NQ04T33VKA10 Datasheet, PDF (1/18 Pages) SynQor Worldwide Headquarters – SIP Single In-Line Package | |||
|
Technical
Specification
NQ04T33VKA10
3.0-5.5V 0.9-3.3V
Input
Outputs
10 Amp
Current
Non
Isolated
SIP
Single In-Line Package
The NiQor⢠SIP DC/DC converter is a non-isolated
buck regulator, which employs synchronous rectification
to achieve extremely high conversion efficiency. The
NiQor family of converters are used predominately in
DPA systems using a front end DC/DC high power brick
(48Vin to low voltage bus). The non-isolated NiQor
converters are then used at the point of load to create
the low voltage outputs required by the design. The
wide trim module can be programmed over a wide
range of output voltages through the use of a single
external resistor. RoHS 5/6 compliant (see page 17).
Non-Isolated
NQ04T33VKA10 wide trim module
Operational Features
⢠Ultra high efficiency, up to 95% at full rated load
⢠Delivers up to 10 Amps of output current with minimal
derating - no heatsink required
⢠Input Voltage Range : 3.0 - 5.5V
⢠Programmable output voltages from 0.85 - 3.6V
⢠On-board input and output filter capacitor
⢠No minimum load requirement means no preload resis-
tors required
Mechanical Features
⢠Industry standard SIP pin-out configuration
⢠Industry standard size: 2.0â x 0.55â x 0.29â
(50.8 x 14 x 7.3mm)
⢠Total weight: 0.30 oz. (9.4 g)
⢠Open frame construction maximizes air flow cooling
⢠Available in both vertical and horizontal mounting
Protection Features
⢠Input under-voltage lockout disables converter at low
input voltage conditions
⢠Temperature compensated over-current shutdown pro-
tects converter from excessive load current or short cir-
cuits
⢠Output over-voltage protection protects load from dam-
aging voltages (>4.4V)
⢠Thermal shutdown protects converter from abnormal
environmental conditions
Safety Features
⢠UL/cUL 60950 recognized (US & Canada)
⢠TUV certified to EN60950
⢠Meets 72/23/EEC and 93/68/EEC directives which
facilitates CE Marking in userâs end product
⢠Board and plastic components meet UL94V-0 flammabil-
ity requirements
Control Features
⢠On/Off control
⢠Output voltage trim (industry standard) permits custom
voltages and voltage margining
⢠Remote Sense (standard option)
Product # NQ04T33VKA10
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2NV4T3F Rev. A
09/06/05