English
Language : 

LPS331AP Datasheet, PDF (9/36 Pages) STMicroelectronics – MEMS pressure sensor: 260-1260 mbar absolute digital output barometer
LPS331AP
4
Application hints
Figure 3. LPS331AP electrical connection
Vdd
Application hints
10µ
Vdd_IO
100nF
16
1
14
13
TOP VIEW
Res
5
9
6
8
Res
4.1
GND
Digital signal from/to signal controller. Signal levels are defined through proper selection of Vdd_
The device core is supplied through the Vdd line. Power supply decoupling capacitors (100
nF ceramic, 10 µF aluminum) should be placed as near as possible to the supply pad of the
device (common design practice).
The functionality of the device and the measured data outputs are selectable and accessible
through the I2C/SPI interface. When using the I2C, CS must be tied high (i.e. connected to
Vdd_IO).
Soldering information
The HCLGA package is compliant with the ECOPACK® standard and it is qualified for
soldering heat resistance according to JEDEC J-STD-020.
Doc ID 022112 Rev 7
9/36