STLUX Datasheet, PDF (87/126 Pages) STMicroelectronics – Digital controllers for lighting and power conversion applications with up to 6 programmable PWM generators, 96 MHz PLL, DALI | |||
|
◁ |
STLUX
Electrical characteristics
The total current consumption is given by Equation 1:
Equation 1
IDD = IDD(Run2) + IDD(ADC2) + IDD(ACU) + IDD(PLL) + IDD(PWM)
where IDD(PWM) = IDD(PWM1) * NPWM
More generally, the PWM current consumption has to be individually evaluated for each
fSMED clock grouping, using Equation 2.
Equation 2
NfSMED
IDDï¨PWMï© = ïi = 1XXXXï»IDDïPWMï¨i1ï©ï ï· Niï½
where i = fSMED clock group index; Ni = PWM number of the i_th clock group;
NfSMED = fSMED clock group number.
DocID027870 Rev 1
87/126
126
|
▷ |