English
Language : 

CLT3-4B Datasheet, PDF (8/13 Pages) STMicroelectronics – Current limited over-voltage protected quad digital termination
Application information
CLT3-4B
The CLT3-4 and the 24 V bus power supply have the same ground COM = GND. The
reverse polarity of the power supply will shutdown the device. And the power supply resistor
RC will limit the default current protecting the power supply pin VC. Its dissipation will be less
than 0.2 W.
Then, the whole module supply voltage rating is extended to from 0 to 30 V to -30 to +30 V.
2.3
EMC considerations
Figure 9 gives a typical application diagram where output capacitors are used to increase
CLT device immunity against fast transient bursts.
Figure 11 gives the printed circuit board layout associated with this schematic.
Refer to AN2527 for EMC considerations.
Figure 9. Robust application diagram
24V
SUPPLY
VCC
VI
2 wires sensor
3 wires sensor
Contact switch
2 wires sensor
VIN
RI
RI
VC
RC
RI
RI
1
COM
IN1
ESD12
IN2
VC
ESDC
IN3
ESD34
IN4
COM
COM
OUT1
COM12
OUT2
COM
COM
OUT3
COM34
OUT4
COM
8/13