English
Language : 

TL081_08 Datasheet, PDF (3/15 Pages) STMicroelectronics – General purpose JFET single operational amplifiers
TL081
2
Absolute maximum ratings
Absolute maximum ratings
Table 1.
Symbol
VCC
Vin
Vid
Ptot
Tstg
Rthja
Rthjc
ESD
Absolute maximum ratings
Parameter
TL081I, AI, BI
TL081C, AC,
BC
Supply voltage (1)
±18
Input voltage (2)
±15
Differential input voltage (3)
±30
Power dissipation
Output short-circuit duration (4)
680
Infinite
Storage temperature range
-65 to +150
Thermal resistance junction to
ambient(5) (6)
SO-8
125
DIP8
85
Thermal resistance junction to case(5) (6)
SO-8
40
DIP8
41
HBM: human body model(7)
500
MM: machine model(8)
200
CDM: charged device model(9)
1.5
Unit
V
V
V
mW
°C
°C/W
°C/W
V
V
kV
1. All voltage values, except differential voltage, are with respect to the zero reference level (ground) of the
supply voltages where the zero reference level is the midpoint between VCC+ and VCC-.
2. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 volts,
whichever is less.
3. Differential voltages are the non-inverting input terminal with respect to the inverting input terminal.
4. The output may be shorted to ground or to either supply. Temperature and/or supply voltages must be
limited to ensure that the dissipation rating is not exceeded.
5. Short-circuits can cause excessive heating and destructive dissipation.
6. Rth are typical values.
7. Human body model: 100 pF discharged through a 1.5kΩ resistor between two pins of the device, done for
all couples of pin combinations with other pins floating.
8. Machine model: a 200 pF cap is charged to the specified voltage, then discharged directly between two
pins of the device with no external series resistor (internal resistor < 5 Ω), done for all couples of pin
combinations with other pins floating.
9. Charged device model: all pins plus package are charged together to the specified voltage and then
discharged directly to the ground.
Table 2. Operating conditions
Symbol
Parameter
TL081I, AI, BI TL081C, AC, BC Unit
VCC Supply voltage range
6 to 36
V
Toper Operating free-air temperature range
-40 to +105
0 to +70
°C
3/15