English
Language : 

M24C04-DRE Datasheet, PDF (29/41 Pages) STMicroelectronics – 4-Kbit serial IC bus EEPROM - 105C operation
M24C04-DRE
DC and AC parameters
Table 10. DC characteristics
Symbol
Parameter
Test conditions (in addition to
those in Table 6 and Table 7)
Min.
Max. Unit
ILI
Input leakage current
(SCL, SDA, Ei)
VIN = VSS or VCC,
device in Standby mode
-
±2
µA
ILO Output leakage current
SDA in Hi-Z, external voltage
applied on SDA: VSS or VCC
-
±2
µA
fC = 400 kHz, VCC = 5.5 V
-
2
mA
fC = 400 kHz, VCC = 2.5 V
-
2
mA
ICC Supply current (Read)
fC = 400 kHz, VCC = 1.8 V
fC = 1 MHz, VCC = 5.5 V
-
1
mA
-
2
mA
fC = 1 MHz, VCC = 2.5 V
-
2
mA
fC = 1 MHz, VCC = 1.8 V
-
2
mA
ICC0 Supply current (Write)
During tW
-
2
mA
Device not selected(1)(2), t° = 85
°C, VIN = VSS or VCC, VCC = 1.8 V
-
1
Device not selected(1)(2), t° = 85
°C, VIN = VSS or VCC, VCC = 2.5 V
-
2
ICC1 Standby supply current
Device not selected(1)(2), t° = 85
°C, VIN = VSS or VCC, VCC = 5.5 V
-
Device not selected(1), t° = 105 °C,
VIN = VSS or VCC, VCC = 1.8 V
-
3
µA
5
Device not selected(1), t° = 105 °C
VIN = VSS or VCC, VCC = 2.5 V
-
5
Device not selected(1), t° = 105 °C,
VIN = VSS or VCC, VCC = 5.5 V
-
10
VIL Input low voltage (SCL, SDA, WC, Ei)(3) -
–0.45 0.3 VCC V
Input high voltage (SCL, SDA)
-
VIH
Input high voltage (WC, Ei)(4)
-
0.7 VCC 6.5
V
0.7 VCC VCC +0.6 V
VOL Output low voltage
VRES (2) Internal reset threshold voltage
IOL = 2.1 mA, VCC = 2.5 V or
IOL = 3 mA, VCC = 5.5 V
IOL = 1 mA, VCC = 1.8 V
-
-
0.4
V
-
0.3
V
0.5
1.5
V
1. The device is not selected after power-up, after a Read instruction (after the Stop condition), or after the
completion of the internal write cycle tW (tW is triggered by the correct decoding of a Write instruction).
2. Characterized only, not 100% tested.
3. Ei inputs should be tied to Vss (see Section 2.3).
4. Ei inputs should be tied to VCC (see Section 2.3).
DocID027421 Rev 1
29/41