English
Language : 

SR176_07 Datasheet, PDF (27/35 Pages) STMicroelectronics – 13.56 MHz, 176-bit short range contactless user EEPROM with 64-bit Unique ID
SR176
8
DC and ac parameters
DC and ac parameters
This section summarizes the operating and measurement conditions, and the dc and ac
characteristics of the device. The parameters in the dc and ac characteristic tables that
follow are derived from tests performed under the Measurement Conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Table 6. Operating conditions
Symbol
Parameter
Min.
Max.
Unit
Wafer
–20
85
°C
TA
Ambient operating temperature
A3, A4, A5
–20
85
°C
Table 7.
Symbol
DC characteristics
Parameter
Condition
Min Typ Max Unit
VCC
VRET
CTUN
Table 8.
Regulated voltage
Retromodulation induced voltage
Internal tuning capacitor
AC characteristics(1)
2.5
3.5 V
ISO 10373-6
20
mV
13.56 MHz
64
pF
Symbol
Parameter
Condition
Min
Max Unit
fCC
MICARRIER
tRFR, tRFF
tRFSBL
tJIT
tMIN CD
External RF signal frequency
Carrier modulation index
10% rise and fall time
10% modulation pulse width
ASK modulation data jitter
Minimum time from carrier
generation to first data
MI=(A-B)/(A+B)
10% to 90%
ETU = 128/fCC
Coupler to SR176
From H-field Min
13.553 13.567 MHz
10
14
%
0.5
1.5
µs
9.44
µs
-2
+2
µs
40
µs
fS
Subcarrier frequency
t0
Antenna reversal delay
t1
Synchronization delay
t2
Answer to new request delay
tDR
Time between request
characters
fCC/16
128/fS
128/fS
14 ETU
Coupler to SR176
847.5
kHz
151
µs
151
µs
132
µs
0
57
µs
tDA
Time between answer
characters
SR176 to Coupler
0
µs
tW
Programming time for WRITE
5
ms
1. All timing measurements were performed on a reference antenna with the following characteristics:
External size: 75 mm x 48 mm
Number of turns: 3
Width of conductor: 1 mm
Space between 2 conductors: 0.4 mm
Value of the coil: 1.4 µH
Tuning Frequency: 14.4 MHz.
27/35