English
Language : 

ALTAIR05T-800 Datasheet, PDF (17/28 Pages) STMicroelectronics – Off-line all-primary-sensing switching regulator
ALTAIR05T-800
Application information
Figure 15. Constant current operation: Switching cycle waveforms
T
IP
t
Is
t
Q
t
IC
I CREF
t
ICRE F
=
−
VC
R
5.6
Voltage feedforward block
The current control structure uses the voltage VC to define the output current, according to
(2). Actually, the CC comparator is affected by an internal propagation delay Td, which
switches off the MOSFET with a peak current than higher the foreseen value.
This current overshoot is equal to:
∆ IP
=
VIN ⋅ Td
LP
(3)
Where LP is the primary inductance.
It introduces an error on the calculated CC setpoint, depending on the input voltage.
The device implements a Line Feedforward function, which solves the issue by introducing
an input voltage dependent offset on the current sense signal, in order to adjust the cycle-
by-cycle current limitation.
The internal schematic is shown in Figure 16.
Doc ID 17957 Rev 1
17/28