Application information
Figure 10. Timing diagram: normal power-up and power-down sequences
Vin
VStart
Vcc
t
VccON
Vccrestart
DRAIN
t
Icharge
5.5 mA
Power-on
Normal operation
CV mode
Normal operation
CC mode
t
Power-off
t
5.3
Zero current detection and triggering block
The zero current detection (ZCD) and triggering blocks switch on the power MOSFET if a
negative-going edge falling below 50 mV is applied to the ZCD/FB pin. To do so, the
triggering block must be previously armed by a positive-going edge exceeding 100 mV.
This feature is used to detect transformer demagnetization for QR operation, where the
signal for the ZCD input is obtained from the transformer’s auxiliary winding used also to
supply the IC.
Figure 11. ZCD block, triggering block
R zcd
ZCD/FB
Rfb
A ux
Z CD
CLA MP
110mV
60mV
BLANKIN G
TIME
Fr om CC/ CV Bloc k
S TA RTE R
TU RN- ON
LO GIC
LEB
S
Q
R
Fr om OC P
To Dr iv er
The triggering block is blanked after MOSFET’s turn-off to prevent any negative-going edge
that follows leakage inductance demagnetization from triggering the ZCD circuit
erroneously.
This blanking time is dependent on the voltage on COMP pin: it is TBLANK = 30 µs for VCOMP
= 0.9 V, and decreases almost linearly down to TBLANK = 6 µs for VCOMP = 1.3 V