L9660 Datasheet, PDF (13/49 Pages) STMicroelectronics – Quad squib driver ASIC for safety application | |||
|
◁ |
L9660
Electrical specifications
Table 7. Squib deployment drivers and diagnostics - DC electrical characteristics (continued)
Symbol
Parameter
Test condition
Min. Typ. Max. Unit
tFETtimeout FET time-out
High squib resistance diagnostics
Normal Conditions
-
-
100
µs
RSQHIZ
High load resistance
threshold
-
1.07
-
2.1
kï
IHR
High resistance current
threshold
-
ISTG
mA
From/CS ï until test results
tDIAGTIMEOUT MOS diagnostic delay time are valid, CSQHx = 0.12µF
-
CSQLx = 0.12µF
-
300
µs
Squib resistance diagnostics
VOH
Output voltage AOUT
VOL
IZ
Tri-State Current AOUT
High saturation voltage;
IAOUT = -500µA
Low Saturation Voltage;
IAOUT = +500µA
AOUT = VDD
AOUT = 0V
RSQB RANGE Load resistance range
-
VAOUT
Resistance measurement
analog output tolerance
VAOUT
VDD ï
=
9----.-17----5--
+
ï¦
ï¨
0.08
ï
-R----S-ï---Q----B--ï¸ï¶
0ï ï£ RSQB < 3.5ï
3.5ï ï£ RSQB ï£ 10ï
VDD-
0.2
-
-
V
-
-
0.2
V
-
-
1
µA
-1
-
µA
0
-
10.0
ï
VAOUT-
0.095V
-
VAOUT+
0.095V
V
VAOUT·
0.95V
-
VAOUT·
1.05V
V
ISRC
Resistance measurement
current source
VDD = 5.0V; VSDIAG = 7.0V
to 37V
38
-
42
mA
ISINK
Resistance measurement
current sink
IPD OFF, VSQLx = 4 V
45
-
57
mA
ISLEW
Vcmpr
Rmeas current di/dt
Voltage threshold on squib
pin to shutdown ISRC
30% - 70% of ISRC
-
2
-
11 mA/µs
2.65
-
3.25
V
tisrcshtdwn
VLSDrsqb
Shutdown time
Guaranteed by design
LSD (V_SQL) voltage during
resistance measure
-
-
-
30
µs
0.8
-
2.2
V
tR_WAIT Rmeas wait time
Wait time before AOUT
voltage is stable for ADC
reading R AOUT= 5.1kï;
-
CAOUT=10nF
-
300
µs
FENx input pins
tFENfilter
IFENPD
Minimum pulse width
Internal pull-down current
-
VIN = VIL to VDD
12
-
16
µs
20
-
50
µA
DocID024714 Rev 2
13/49