AN2846
Application guidelines
1.2.5
Input state monitoring
The state of each of the 8 monitoring LEDs is an image of the 8 filtered input states. All the
monitoring LED cathodes have to be connected to ground. In the on state a current of ILIM
reduced by 0.15 mA is available for each LED. In case of a LED not being used, the LED
output pin must be connected to the ground COMP to allow the input current to flow back to
the ground.
The LEDs must be chosen with a VF voltage less then 2.7 V (at minimum operating
temperature -25 °C).
1.3
1.3.1
Monitoring functions and regulator
VCC monitoring
The power bus voltage connected to VCC is sensed by the VCS pin through a resistor bridge.
The VCS threshold voltage is typically 1.25 V with a hysteresis of 100 mV. Designers can
easily set their own alarm detection voltage by an appropriate resistor bridge (see
Figure 12) using the formula:
VCC _ min
= V CS
(1 +
RS )
R PD
Figure 12. UVA comparator
VCC
RS
VCS
R PD
VDD
VBG=1.25V
UVA
1ms delay
COM
For example, the resistor bridge consisting of RS = 1.5 MΩ and RPD = 120 kΩ produces UVA
activation when VCC drops below 17 V. The UVA activation has no effect on SCLT3-8
behavior but the information is transmitted trough the SPI bus by setting bit 7 to low state in
the control bits register (see Figure 13 and Figure 14).
To eliminate any short voltage disturbances that could trigger the UVA, a 1 ms delay circuit
has been inserted in the output line of the UVA comparator.
Doc ID 15130 Rev 1
11/35