English
Language : 

GDT-C6M Datasheet, PDF (2/3 Pages) StarHope – Gas Discharge Tube C6M Series
SPSEMI
Dimensions
8±0 . 2
GDT/C6M Series
Φ6±0 . 2
4 . 4±0 . 3
4 . 4±0 . 3
Electrical Characteristics
Φ0. 8±0.1
Dimensions in millimeters
Part Number
With
Wire
C6M07R
Without
Wire
C6M07
DC
Impulse
Nom.
Nom.
Nom.
Spark-over Spark-over Impulse Alternating Impulse
Voltage Voltage Discharge
(@100V/s) (@1KV/μs)
(V)
(V)
Current
(@8/20μs)
(KA)
Discharge
Current
(@50HZ)
(A)
Discharge
Current
(@8/20μs)
(KA)
75±20%
≦600
5×2
10
10
Insulation
Resistance Capacitance
(pF)
(GΩ)
(@DC)
(V)
>1
25
<1
C6M09R C6M09 90±20%
≦600
5×2
10
10
>1
50
<1
C6M15R C6M15 150±20% ≦650
5×2
10
10
>1
50
<1
C6M23R C6M23 230±20% ≦650
5×2
10
10
>1 100
<1
C6M35R C6M35 350±20% ≦700
5×2
10
10
>1 100
<1
C6M47R C6M47 470±20% ≦750
5×2
10
10
>1 250
<1
C6M60R C6M60 600±20% ≦950
5×2
10
10
>1 250
<1
Packaging Speci Cations
Packaging:100 pieces bulk
Initial Characteristics
Test Item
DC-Spark-Over Voltage
Vs
Insulation
Resistance
Test Method
Add and measure the DC Voltage gradually
Maxto get the discharge threshold voltage.
The measuring current is 1mA/1 second max.(1sec).(1mA)
Measure the insulation resistance of two end of
leadwire under the specified DC voltage.
Capacitance C(pF)
Electrostatic Capacitance under the test condition
of 1KHz,DC 6V(max).
Specification
It depands on each spec.
100MΩ min.
0.8pF max.
REV.2017.04.06
www.spsemi.cn
Page 2 of 3