English
Language : 

CY28412 Datasheet, PDF (12/16 Pages) SpectraLinear Inc – Clock Generator for Intel® Grantsdale Chipset
CY28412
AC Electrical Specifications
Parameter
Description
Condition
Min.
Crystal
TDC
XIN Duty Cycle
The device will operate reliably with input duty
cycles up to 30/70 but the REF clock duty cycle 47.5
will not be within specification
TPERIOD XIN Period
When XIN is driven from an external clock
source
69.841
TR / TF XIN Rise and Fall Times
TCCJ
XIN Cycle to Cycle Jitter
LACC
Long-term Accuracy
CPU at 0.7V
Measured between 0.3VDD and 0.7VDD
–
As an average over 1-Ps duration
–
Over 150 ms
–
TDC
CPUT and CPUC Duty Cycle
Measured at crossing point VOX
TPERIOD 100 MHz CPUT and CPUC Period
Measured at crossing point VOX
TPERIOD 133 MHz CPUT and CPUC Period
Measured at crossing point VOX
TPERIOD 166 MHz CPUT and CPUC Period
Measured at crossing point VOX
TPERIOD 200 MHz CPUT and CPUC Period
Measured at crossing point VOX
TPERIOD 266 MHz CPUT and CPUC Period
Measured at crossing point VOX
TPERIOD 333 MHz CPUT and CPUC Period
Measured at crossing point VOX
TPERIOD 400 MHz CPUT and CPUC Period
Measured at crossing point VOX
TPERIODSS 100 MHz CPUT and CPUC Period, SSC Measured at crossing point VOX
TPERIODSS 133 MHz CPUT and CPUC Period, SSC Measured at crossing point VOX
TPERIODSS 166 MHz CPUT and CPUC Period, SSC Measured at crossing point VOX
TPERIODSS 200 MHz CPUT and CPUC Period, SSC Measured at crossing point VOX
TPERIODSS 266 MHz CPUT and CPUC Period, SSC Measured at crossing point VOX
TPERIODSS 333 MHz CPUT and CPUC Period, SSC Measured at crossing point VOX
TPERIODSS 400 MHz CPUT and CPUC Period, SSC Measured at crossing point VOX
TSKEW
Any CPUT/C to CPUT/C Clock Skew, Measured at crossing point VOX
SSC
45
9.9970
7.4978
5.9982
4.9985
3.7489
2.9991
2.4993
9.9970
7.4978
5.9982
4.9985
3.7489
2.9991
2.4993
–
TCCJ
TCCJ2
TSKEW2
TR / TF
TRFM
'TR
'TF
VHIGH
VLOW
VOX
VOVS
CPUT/C Cycle to Cycle Jitter
CPU2_ITP Cycle to Cycle Jitter
CPU2_ITP to CPU0 Clock Skew
CPUT and CPUC Rise and Fall Times
Rise/Fall Matching
Rise Time Variation
Fall Time Variation
Voltage High
Voltage Low
Crossing Point Voltage at 0.7V Swing
Maximum Overshoot Voltage
Measured at crossing point VOX
Measured at crossing point VOX
Measured at crossing point VOX
Measured from VOL = 0.175 to VOH = 0.525V
Determined as a fraction of 2*(TR – TF)/(TR + TF)
Math averages Figure 8
Math averages Figure 8
–
–
–
175
–
–
–
660
–150
250
–
VUDS
VRB
SRC
Minimum Undershoot Voltage
Ring Back Voltage
See Figure 8. Measure SE
TDC
SRCT and SRCC Duty Cycle
Measured at crossing point VOX
TPERIOD 100 MHz SRCT and SRCC Period
Measured at crossing point VOX
TPERIODSS 100 MHz SRCT and SRCC Period, SSC Measured at crossing point VOX
–0.3
–
45
9.9970
9.9970
Max. Unit
52.5 %
71.0 ns
10.0 ns
500 ps
300 ppm
55
%
10.003 ns
7.5023 ns
6.0018 ns
5.0015 ns
3.7511 ns
3.0009 ns
2.5008 ns
10.0533 ns
7.5400 ns
6.0320 ns
5.0266 ns
3.7700 ns
3.0160 ns
2.5133 ns
100 ps
85
ps
125 ps
150 ps
700 ps
20
%
125 ps
125 ps
850 mv
–
mv
550 mv
VHIGH +
0.3
V
–
V
0.2
V
55
%
10.003 ns
10.0533 ns
Rev 1.0, November 20, 2006
Page 12 of 16