English
Language : 

XPP-XG-N2-CDFA Datasheet, PDF (8/12 Pages) –
XPP-XG-N2-CDFA
Recommended Interface Circuit)
4. These are the differential transmitter inputs. They are AC coupled differential lines with 100Ω differential
termination inside the module. The AC coupling is done inside the module and is thus not required on the
host board. (See Recommended Interface Circuit)
Diagnostics
Table 7– Diagnostics
Address(A0
h)
96
100
102
104
106
Parameter
Temperature
Bias Current
Tx Power
Rx Power
Voltage
Table 8– EEPROM Serial ID (A0h)
Range
-5 to 70
5 to 150
2 to 8
-30 to -8
0 to Vcc
Accuracy
±3
±10%
±3
±3
±3%
Unit
ºC
mA
dBm
dBm
V
Notes
LSB equal to 4uA
LSB equal to 0.1uW
LSB equal to 0.1uW
Name of Field
Identifier
Ext. Identifier
Connector
Transceiver
Encoding
BR_MIN
BR_MAX
Description of Field
Type of transceiver
Address
128
Extended identifier of type of transceiver
129
Code for connector type
130
131
132
133
Code for electronic compatibility
134
or optical compatibility
135
136
137
138
Code for high speed serial encoding
algorithm
139
Minimum bit rate, units of 100
140
MBits/s.
Maximum bit rate, units of 100
141
MBits/s
8
Hex
ASCII
06
XFP
>3.5W max
power
E8
dissipation;
with CDR
01
SC/UPC
10GBASE-E
00
W
10
00
00
00
00
00
00
10
NRZ
63
9.95Gbps
63
9.95Gbps
DS- 6774 Rev 01 2011-10-27