English
Language : 

ICX282AQ Datasheet, PDF (17/48 Pages) Sony Corporation – Diagonal 11mm (Type 2/3) Frame Readout CCD Image Sensor with Square Pixel for Color Cameras
ICX282AQ
4. Video signal shading
Set to the standard imaging condition II. With the lens diaphragm at F5.6 to F8, adjusting the luminous
intensity so that the average value of the Gr signal output is 150mV. Then measure the maximum value
(Grmax [mV]) and minimum value (Grmin [mV]) of the Gr signal output and substitute the values into the
following formula.
SHg = (Grmax – Grmin)/150 × 100 [%]
5. Dark signal
Measure the average value of the signal output (Vdt [mV]) with the device ambient temperature of 60°C
and the device in the light-obstructed state, using the horizontal idle transfer level as a reference.
6. Dark signal shading
After measuring 5, measure the maximum (Vdmax [mV]) and minimum (Vdmin [mV]) values of the dark
signal output and substitute the values into the following formula.
∆Vdt = Vdmax – Vdmin [mV]
7. Line crawl
Set to the standard imaging condition II. Adjusting the luminous intensity so that the average value of the
Gr signal output is 150mV, and then insert R, G and B filters and measure the difference between G signal
lines (∆Glr, ∆Glg, ∆Glb [mV]) as well as the average value of the G signal output (Gar, Gag, Gab).
Substitute the values into the following formula.
Lci =
∆Gli
Gai
× 100 [%] (i = r, g, b)
8. Lag
Adjust the Gr channel output generated by the strobe light to 150mV. After setting the strobe light so that it
strobes with the following timing, measure the residual signal amount (Vlag). Substitute the value into the
following formula.
Lag = (Vlag/150) × 100 [%]
VD
V1A/V1B/V1C
Strobe light timing
Output
Light
Gr signal output 150mV
– 17 –
Vlag (lag)