English
Language : 

CXA1690Q Datasheet, PDF (1/18 Pages) Sony Corporation – Head Amplifier for Digital CCD Cameras
CXA1690Q
Head Amplifier for Digital CCD Cameras
Description
The CXA1690Q is a bipolar IC developed as a
head amplifier for digital CCD cameras. The
CXA1690Q provides the following functions:
correlated double sampling, AGC for CCD signals,
GCA for chroma signals, GCA for line signals,
sample and hold for A/D converters, blanking, and
reference voltage output/output driver for A/D
converters.
Features
• Permits higher sensitivity with a high-gain AGC
amplifier
• Blanking function for the purpose of calibrating the
deviation in black levels of the CCD output signals
• Permits output offset adjustment
• Provides a regulator output pin for the reference
voltage for A/D converters
• Built-in GCA that amplifies video signals (chroma
and line signals) from an external source
• Built-in sample-and-hold circuits (for both camera
signals and video signals) required by external A/D
converters
32 pin QFP (Plastic)
Structure
Bipolar silicon monolithic IC
Applications
Digital CCD cameras
Absolute Maximum Ratings
• Supply voltage
• Operating temperature
• Storage temperature
• Allowable power dissipation
VCC
Topr
Tstg
PD
14
V
–20 to +75 °C
–65 to +150 °C
460
mW
Operating Conditions
Supply voltage
VCC1, 2, 3 4.5 to 5
V
Sony reserves the right to change products and specifications without prior notice. This information does not convey any license by
any implication or otherwise under any patents or other right. Application circuits shown, if any, are typical examples illustrating the
operation of the devices. Sony cannot assume responsibility for any problems arising out of the use of these circuits.
–1–
E93X02A8X-PS