English
Language : 

CAP1014 Datasheet, PDF (47/84 Pages) SMSC Corporation – Multiple Channel Capacitive Touch Sensor and LED Driver
Multiple Channel Capacitive Touch Sensor and LED Driver
Datasheet
Table 5.24 RPT_RATE_B / SL / PH and M_PRESS Bit Decode
RPT_RATE_B / RPT_RATE_SL / RPT_RATE_PH / M_PRESS[3:0]
3
2
1
0
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
0
0
1
0
1
0
1
1
0
0
1
1
1
1
0
0
0
1
0
0
1
1
0
1
0
1
0
1
1
1
1
0
0
1
1
0
1
1
1
1
0
1
1
1
1
INTERRUPT REPEAT
RATE OR M_PRESS
TIME
35ms
70ms
105ms
140ms
175ms
210ms
245ms
280ms
315ms
350ms
385ms
420ms
455ms
490ms
525ms
560ms
5.17 Group Configuration Register 1
Table 5.25 Group Configuration Register 1
ADDR R/W
REGISTER
B7
B6
B5
B4
23h
R/W
Group
Configuration 1
RPT_RATE_PH[3:0]
B3
B2
B1
B0 DEFAULT
M_PRESS[3:0]
47h
Bits 7-4 - RPT_RATE_PH[3:0] - (default 0100b) Determines the time duration between interrupt
assertions when auto repeat is enabled. This setting applies when a press and hold condition is
detected on the on the Grouped Sensors (see Section 4.5.2). The resolution is 35ms the range is from
35ms to 560ms as shown in Table 5.24.
Bits 3- 0 - M_PRESS[3:0] - (default 0111b) - Determines the minimum amount of time that a sensor
in the Group must detect a button press to detect a Press and Hold event. If the sensor detects a
touch for longer than the M_PRESS[3:0] settings, then a Press and Hold event is detected. This has
no affect on whether a slide is detected within the group. If a slide is detected before or after the press
has been confirmed, it is treated as a separate event.
SMSC CAP1014
47
DATASHEET
Revision 1.65 (08-11-09)