English
Language : 

AAT2400 Datasheet, PDF (7/32 Pages) Skyworks Solutions Inc. – Sixteen-Channel White LED Driver Solution
DATA SHEET
AAT2400/2401
Sixteen-Channel White LED Driver Solution
with Full LED Current and Timing Control
Electrical Characteristics1
VIN=24V; CIN = 4.7µF, COUT = 4.7µF; CVCC = 2.2µF; L1 = 4.2µH; RSET =10.2kΩ (ICSx = 60mA); TA = -40oC to 85oC unless
otherwise noted. Typical values are at TA = 25oC.
Symbol Description
Logic Level Outputs: SDO, FAULT
VCCIO
VCC I/O Voltage Range
VO(H)
Output Logic Level High
VO(L)
Output Logic Level Low
VFAULTLOW
FAULT Logic Output Low
ISINK
FAULT Logic Hi Leakage
Interface: VSYNC, GSCLK
FVSYNC
VSYNC Maximum Frequency
FGSCLK
GSCLK Frequency
tSETUP(SU_VS) Minimum VSYNC Setup Time
tHOLD(H_VS) Minimum VSYNC Hold Time
TGS(HI/LO_ MIN) Minimum GSCLK Clock High/Low Time
tSCLK(HI/LO_ MIN) Minimum SCLK Clock High/Low Time
tVS(HI/LO_ MIN) Minimum VSYNC Clock High/Low Time
SPI Interface: SDI, SDO, SCLK, CSB
FMAX
Maximum Clock Frequency
tSETUP(SU_ SDI) Minimum SDI Setup Time
tSETUP(SU_CS) Minimum CSB Setup Time
tHOLD(H_ SDI) Minimum SDI Hold Time
Thermal Protection
TJ2(SD)
TJ Thermal Shutdown Threshold
TJ2(HYS)
TJ Thermal Shutdown Hysteresis
TJ1(SD)
TJ Thermal Warning Threshold
TJ1(HYS)
TJ Thermal Warning Hysteresis
Conditions
No Load
ISOURCE = 4mA, VCCIO = 3.3V
ISINK = -4mA
VFAULT = 5.5V
GSCLK, VSYNC
GSCLK, VSYNC
SDI, SCLK
CSB, SDI
SDI, SCLK
Reset Thermal Threshold
CTL1 and CTL2 Registers are Reset to 0
Warning Thermal Threshold
Min
2.97
2.4
55
Typ
3.3
1
24
24
32
32
32
30
24
24
24
140
15
120
15
Max
3.63
0.4
0.4
1
250
Units
V
V
V
V
µA
Hz
MHz
ns
ns
ns
ns
ns
MHz
ns
ns
ns
°C
°C
°C
°C