English
Language : 

SKY72302 Datasheet, PDF (5/21 Pages) Skyworks Solutions Inc. – Spur-Free, 6.1 GHz Dual Fractional-N Frequency Synthesizer
DATA SHEET • SKY72302 FREQUENCY SYNTHESIZER
Fractional-N Applications. The desired division ratio for the
main synthesizer is given by:
Nfraction al = (---4F----V×----C-F--O--d--_-i--mv--_-a--r-i-e-n-f--)-
The desired division ratio for the auxiliary synthesizer is given by:
Nf rac ti on al
=
F-----V---C---O----_---a---u---x
Fdiv_ref
where Nfractional must be between 150 and 2150 for the main
synthesizer or between 37.5 and 537.5 for the auxiliary
synthesizer.
The value to be programmed by the Main or Auxiliary Divider
Register is given by:
N reg = Round( N fractional )− 32
NOTE: The Round function rounds the number to the nearest
integer.
When in fractional mode, allowed values for Nreg are from 6 to 505
inclusive.
The value to be programmed by either of the MSB/LSB Dividend
Registers or the Auxiliary Dividend Register is given by:
dividend = Round [ divider ×( N fractional − N reg − 32 )]
where the divider is either 1024 in 10-bit mode or 262144 in
18-bit mode. Therefore, the dividend is a signed binary value
either 10 or 18 bits long.
NOTE: Because of the high fractionality of the SKY72302, there is
no practical need for any integer relationship between the
reference frequency and the channel spacing or desired
VCO frequencies.
Sample calculations for two fractional-N applications are provided
in Figure 4.
Integer-N Applications. The desired division ratio for the main or
auxiliary synthesizer is given by:
N = FF int eger
vco _ main
div _ ref
where Ninteger is an integer number from 32 to 543.
The value to be programmed by the Main or Auxiliary Divider
Register is given by:
N reg = Nint eger − 32
When in integer mode, allowed values for Nreg are from 0 to 511
for both the main and auxiliary synthesizers.
NOTE: As with all integer-N synthesizers, the minimum step size
is related to the crystal frequency and reference frequency
division ratio.
A sample calculation for an integer-N application is provided in
Figure 5.
Register Loading Order. In applications where the main
synthesizer is in 18-bit mode, the Main Dividend MSB Register
holds the 10 MSBs of the dividend and the Main Dividend LSB
Register holds the 8 LSBs of the dividend. The registers that
control the main synthesizer’s divide ratio are to be loaded in the
following order:
• Main Divider Register
• Main Dividend LSB Register
• Main Dividend MSB Register (at which point the new divide ratio
takes effect)
In applications where the main synthesizer is in 10-bit mode, the
Main Dividend MSB Register holds the 10 bits of the dividend. The
registers that control the main synthesizer’s divide ratio are to be
loaded in the following order:
• Main Divider Register
• Main Dividend MSB Register (at which point the new divide ratio
takes effect)
For the auxiliary synthesizer, the Auxiliary Dividend Register holds
the 10 bits of the dividend. The registers that control the auxiliary
synthesizer’s divide ratio are to be loaded in the following order:
• Auxiliary Divider Register
• Auxiliary Dividend Register (at which point the new divide ratio
takes effect)
NOTE: When in integer mode, the new divide ratios take effect as
soon as the Main or Auxiliary Divider Register is loaded.
Direct Digital Modulation
The high fractionality and small step size of the SKY72302 allow
the user to tune to practically any frequency in the VCO’s
operating range. This allows direct digital modulation by
programming the different desired frequencies at precise
instants. Typically, the channel frequency is programmed by the
Main Divider and MSB/LSB Dividend Registers, and the
instantaneous frequency offset from the carrier is programmed by
the Modulation Data Register.
The Modulation Data Register can be accessed in three ways as
defined in the following subsections.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
101216K • Skyworks Proprietary and Confidential information • Products and Product Information are Subject to Change Without Notice • May 16, 2007
5