English
Language : 

AAT2556 Datasheet, PDF (5/27 Pages) Advanced Analogic Technologies – Battery Charger and Step-Down Converter for Portable Applications
DATA SHEET
AAT2556
Battery Charger and Step-Down Converter for Portable Applications
Electrical Characteristics1
VADP = 5V; TA = -40°C to +85°C, unless otherwise noted. Typical values are TA = 25°C.
Symbol Description
Battery Charger
Operation
VADP
VUVLO
Adapter Voltage Range
Under-Voltage Lockout (UVLO)
UVLO Hysteresis
IOP
Operating Current
ISHUTDOWN
Shutdown Current
ILEAKAGE
Reverse Leakage Current from BAT Pin
Voltage Regulation
VBAT_EOC
End of Charge Accuracy
VCH/VCH Output Charge Voltage Tolerance
VMIN
Preconditioning Voltage Threshold
VRCH
Battery Recharge Voltage Threshold
Current Regulation
ICH
Charge Current Programmable Range
ICH/ICH Charge Current Regulation Tolerance
VSET
ISET Pin Voltage
KI_A
Current Set Factor: ICH/ISET
Charging Devices
RDS(ON)
Charging Transistor On Resistance
Logic Control/Protection
VEN(H)
VEN(L)
VSTAT
ISTAT
VOVP
ITK/ICHG
ITERM/ICHG
Input High Threshold
Input Low Threshold
Output Low Voltage
STAT Pin Current Sink Capability
Over-Voltage Protection Threshold
Pre-Charge Current
Charge Termination Threshold Current
Conditions
Rising Edge
Charge Current = 200mA
VBAT = 4.25V, EN = GND
VBAT = 4V, ADP Pin Open
Measured from VBAT_EOC
VADP = 5.5V
STAT Pin Sinks 4mA
ICH = 100mA
Min Typ Max Units
4.0
6.5
V
3
4
V
150
mV
0.5
1
mA
0.3
1
μA
0.4
2
μA
4.158 4.20 4.242
V
0.5
%
2.85
3.0
3.15
V
-0.1
V
15
500
mA
10
%
2
V
800
0.9
1.1

1.6
V
0.4
V
0.4
V
8
mA
4.4
V
10
%
10
%
1. The AAT2556 output charge voltage is specified over the 0° to 70°C ambient temperature range; operation over the -25°C to +85°C temperature range is guaranteed by
design.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
202177B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013