English
Language : 

AAT3673 Datasheet, PDF (4/28 Pages) Skyworks Solutions Inc. – 1.6A Dynamic Battery Charger and Power Manager
DATA SHEET
AAT3673
1.6A Dynamic Battery Charger and Power Manager
Electrical Characteristics
VADP = 5V, TA = -25°C to +85°C; unless otherwise noted, typical values are TA = 25°C.
Symbol
Operation
VOVP
VADP
VBAT
Description
Input Over Voltage Protection Range
AC Adapter / USB Operating Voltage Range
Battery Operating Voltage Range
VOUT
ADP to OUT Voltage Regulation
VDO
VUVLO_ADP
ADP to OUT Regulator Dropout1
ADP Under-Voltage Lockout
VUVLO_BAT
IADP_OP
IADP_SHDN
IBAT_OP
BAT Under-Voltage Lockout
ADP Normal Operating Current
ADP Shutdown Mode Current
(OVP is Still Active)
Battery Operating Current
IBAT_SLP
Battery Sleep Current
IBAT_SHDN
Leakage Current from BAT Pin
Over-Voltage Protection
VOVPT
Over-Voltage Protection Trip Voltage
VDO_OVP
Dropout Voltage Between ADP and BYP Pins
TRESPOV
Over-Voltage Protection Response Time
Options -1, -2, -3
TOVPON_130μs OVP Switch Release Delay Time
TOVPSTARTON_130μs OVP Switch Start Up Delay Time
Options -4, -5, -6
TOVPON_80ms OVP Switch Release Delay Time
TOVPSTARTON_80ms OVP Switch Start Up Delay Time
Power Switches
RDS(ON)_SWA ADP-to-OUT FET On Resistance
RDS(ON)_SWB BAT-to-OUT FET On Resistance
RDS(ON)_CHA ADP Battery Charging FET On-Resistance
Battery Charge Voltage Regulation
VCO(REG)
VMIN
Output Charge Voltage Regulation
Preconditioning Voltage Threshold
VRCH
Battery Recharge Voltage Threshold
VCHR_TH
VCHR_REG
Default ADP Charge Reduction Threshold
CHRADP Pin Voltage Accuracy
Conditions
VADP = 5V, IOUT = 100mA, TA = 25°C
VADP = 4.8V to 6.5V, IOUT = 0mA to
400mA, TA = -25°C to +85°C
IOUT = 400mA
Rising Edge
Hysteresis
Rising Edge
Hysteresis
VADP = 5V, VEN = 0V, ICC = 1A
VADP = 5V, VEN = 5V, VENBAT = 5V,
No Load
VBAT = VCO(REG), VADP = VENBAT = GND
No Load
VBAT = VCO(REG), VADP = 5V,
VEN = VENBAT = 5V
VBAT = VCO(REG), VENBAT = VADP = 5V
VADP Rising Edge
Hysteresis
VADP = 5V, IADP = 500mA
Step up VADP from 6V to 8V
VADP voltage step down from 8V to
6V, RLOAD = 100Ω, CBYP = 1μF
VADP voltage step up from 0V to
5V, RLOAD = 100Ω, CBYP = 1μF
VADP voltage step down from 8V to
6V, RLOAD = 100Ω, CBYP = 1μF
VADP voltage step up from 0V to
5V, RLOAD = 100Ω, CBYP = 1μF
VADP = 5.0V
VBAT = 4.1V
VADP = 5.0V
CHRADP Open; Reduce Charge
Current When ADP is Below VCHR_TH
VADP = 4.5V
Min
4.0
3.0
4.33
4.26
2.8
6.5
4.158
2.8
VCO(REG)
- 0.17
1.9
Typ
4.40
4.4
150
3.1
0.1
2.9
0.1
0.8
100
5
6.75
100
100
0.5
130
150
80
80
600
60
600
4.20
2.9
VCO(REG)
- 0.1
4.5
2.0
Max
28
6.5
VCO(REG)
4.47
4.54
250
3.9
3.0
1.6
360
250
10
2
7.0
200
4.242
3.0
VCO(REG)
- 0.05
2.1
Units
V
mV
V
mA
μA
V
mV
μs
μs
ms
mΩ
V
1. VDO is defined as VADP - VOUT when VOUT is 98% of normal.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
4
201881B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • April 25, 2012