English
Language : 

SKY67159-396LF Datasheet, PDF (2/18 Pages) Skyworks Solutions Inc. – 200 to 3800 MHz Broadband Low-Noise Amplifier
DATA SHEET • SKY67159-396LF: BROADBAND LOW-NOISE AMPLIFIER
Table 1. SKY67159-396LF Signal Descriptions
Pin
Name
Description
1 N/C
No connection. May be left open, connected to
VDD, or connected to ground with no change in
performance.
2 RFIN
RF input. DC blocking capacitor required.
3 VBIAS
Bias voltage for input gate. External resistor sets
current consumption.
4 N/C
No connection. May be connected to ground with
no change in performance.
Pin
Name
5
N/C
6
ENABLE
7
RFOUT/VDD
8
N/C
Description
No connection. May be connected to ground with
no change in performance.
Enable pin. Active low = amplifier ON state
RF output. Apply VDD through RF choke inductor.
DC blocking capacitor required.
No connection. May be connected to ground with
no change in performance.
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY67159-396LF are
provided in Table 2. Electrical specifications are provided in
Tables 3 through 5. Typical performance characteristics are
illustrated in Figures 3 through 27.
Table 2. SKY67159-396LF Absolute Maximum Ratings (Note 1)
Parameter
Symbol
Minimum
Maximum
Units
Supply voltage
VDD
5.5
V
Quiescent supply current
ICQ
100
mA
RF input power (C/W)
PIN
+21
dBm
Storage temperature
TSTG
–40
+150
C
Operating temperature
TA
–40
+105
C
Junction temperature
TJ
+150
C
Electrostatic discharge:
ESD
Charged Device Model (CDM), Class 4
Human Body Model (HBM), Class 1A
Machine Model (MM), Class A
1000
V
250
V
30
V
Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
2
May 12, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203397B