DATA SHEET • SKY67013-396LF: LOW-NOISE, LOW-CURRENT AMPLIFIER
Table 1. SKY67013-396LF Signal Descriptions
Pin
Name
Description
1
VBIAS
Bias for first stage amplifier. External
resistor sets current consumption.
2
RF_IN
RF input. DC blocking capacitor required.
3
N/C
4
N/C
No connection. May be connected to ground
with no change in performance.
No connection. May be connected to ground
with no change in performance.
Pin
Name
5
N/C
6
N/C
7
RF_OUT/VDD
8
N/C
Description
No connection. May be connected to ground
with no change in performance.
No connection. May be connected to ground
with no change in performance.
RF output. Apply VDD through RF choke
inductor. DC blocking capacitor required.
No connection. May be connected to ground
with no change in performance.
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY67013-396LF are
provided in Table 2. Electrical specifications are provided in
Tables 3 (15 mA operation) and 4 (5 mA operation).
Typical performance characteristics of the SKY67013-396LF are
illustrated in Figures 3 through 15 (for 15 mA quiescent current),
and Figures 16 through 26 (for 5 mA quiescent current).
Table 2. SKY67013-396LF Absolute Maximum Ratings (Note 1)
Parameter
Symbol
Minimum
Typical
Maximum
Units
Supply voltage
VDD
3.3
5.5
V
Drain current
IDD
15
50
mA
RF input power
PIN
+18
dBm
Storage temperature
TSTG
–65
+25
+125
C
Operating temperature
TA
–40
+25
+85
C
Thermal resistance
ΘJC
128
C/W
Electrostatic discharge:
ESD
Human Body Model (HBM), Class 1A
500
V
Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
2
April 22, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201657F