English
Language : 

SKY65099-360LF Datasheet, PDF (2/13 Pages) Skyworks Solutions Inc. – 700 to 2700 MHz Broadband Linear Amplifier Driver
DATA SHEET • SKY65099-360LF: BROADBAND LINEAR AMPLIFIER DRIVER
Table 1. SKY65099-360LF Signal Descriptions
Pin
Name
1
REXT1
2
GND
3
RFIN
4
N/U
5
N/U
6
RFOUT1
7
RFOUT2
8
REXT2
Pin 1 of external bias resistor
Ground
RF input port
Not used (may be grounded)
Not used (may be grounded)
RF output port 1
RF output port 2
Pin 2 of external bias resistor
Description
Technical Description
The SKY65099-360LF is a single-stage, low-noise PA that
operates with a single 5 V power supply connected through an RF
choke (inductor L1) to the output signal (pin 7). The bias current is
set by the on-chip active bias composed of current mirror and
reference voltage transistors, which allow excellent gain tracking
over temperature and voltage variations. The device is externally
RF matched using surface mount components to facilitate
operation over a frequency range of 700 to 2700 MHz.
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY65099-360LF are
provided in Table 2. The recommended operating conditions are
specified in Table 3.
Electrical specifications are provided in Table 4 (720 to 840 MHz),
Table 5 (2100 to 2200 MHz), and Table 6 (2500 to 2700 MHz).
Table 2. SKY65099-360LF Absolute Maximum Ratings (Note 1)
Parameter
Symbol
Min
Max
Units
Supply voltage
VCC
–0.3
+5.5
V
RF input power
PIN
+10
dBm
Supply current @ P1dB
ICC
400
mA
Power dissipation
PDISS
0.9
W
Operating case temperature
TC
–40
+85
°C
Storage temperature
TST
–55
+150
°C
Junction temperature (@ P1dB = –10 dBm) TJ
+150
°C
Thermal resistance (@ P1dB = –10 dBm)
ΘJC
85
°C/W
Electrostatic discharge:
ESD
Charged Device Model (CDM), Class 4
Human Body Model (HBM), Class 1C
Machine Model (MM), Class A
1000
V
1500
V
50
V
Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal values. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This
device must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the
human body or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all
times.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
2
November 10, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202024C