English
Language : 

SKY13354-368LF Datasheet, PDF (2/10 Pages) Skyworks Solutions Inc. – 0.1 to 3.0 GHz Dual SPDT Crossed Switch
DATA SHEET • SKY13354-368LF: DUAL SPDT CROSSED SWITCH
Table 1. SKY13354-368LF Signal Descriptions
Pin
Name
Description
1
RF1B
RF port 1B. Must be DC blocked for proper
operation.
2
N/C
No connection. May be connected to ground
with no change in performance.
3
RF2A
RF port 2A. Must be DC blocked for proper
operation.
4
RF2B
RF port 2B. Must be DC blocked for proper
operation.
5
V1
DC control voltage 1. See Table 5.
6
N/C
No connection. May be connected to ground
with no change in performance.
Note: Bottom ground paddle must be connected to ground through a low impedance path.
Pin
Name
7
RFCB
8
N/C
9
RFCA
10 N/C
11 V2
12 RF1A
Description
RF common port B (antenna). Must be DC
blocked for proper operation.
No connection. May be connected to ground
with no change in performance.
RF common port A (antenna). Must be DC
blocked for proper operation.
No connection. May be connected to ground
with no change in performance.
DC control voltage 2. See Table 5.
RF port 1A. Must be DC blocked for proper
operation.
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY13354-368LF are
provided in Table 2. The recommended operating conditions are
specified in Table 3 and electrical specifications are provided in
Table 4.
Typical performance characteristics of the SKY13354-368LF are
illustrated in Figures 3 through 8.
The state of the SKY13354-368LF is determined by the logic
provided in Table 5.
Table 2. SKY13354-368LF Absolute Maximum Ratings
Parameter
Symbol
Minimum
Maximum
Units
Input power
PIN
+30
dBm
Control voltage
V1, V2
6
V
Storage temperature
TSTG
–40
+125
C
Operating temperature
TOP
–40
+85
C
Note: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Table 3. SKY13354-368LF Recommended Operating Conditions
Parameter
Symbol
Minimum
Typical
Maximum
Units
Frequency
f
0.1
3.0
GHz
Control voltage (V1, V2)
VCTL
1.6
3.0
5.0
V
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
2