English
Language : 

AAT1282 Datasheet, PDF (14/22 Pages) Skyworks Solutions Inc. – 2A Driver for High Intensity LED Camera Flash
DATA SHEET
AAT1282
2A Driver for High Intensity LED Camera Flash
Device Register Information
To program the register through the I2C interface, the
master needs to send the AAT1282’s device address,
0x37 (Hex), first, and then sends an 8-bit register
address and 8-bit data. The AAT1282 has two registers,
Register 0 and Register 1. If no instruction is written to
the register, the default value is applied.
Register 0 (REG0), Register Address: 00h
Bits [7:4] Program the movie-mode current with 16 different percentage levels.
Bits [3:0] Program the flash safety timeout with 16 different fractions from the hardware configuration, CT.
MSB
LSB
7
6
5
4
3
2
1
0
Figure 6: AAT1282 Register 0 Programming.
Flash Safety
Timeout
0000 = 16/16(default)
0001 = 15/16
0010 = 14/16
0011 = 13/16
0100 = 12/16
0101 = 11/16
0110 = 10/16
0111 = 9/16
1000 = 8/16
1001 = 7/16
1010 = 6/16
1011 = 5/16
1100 = 4/16
1101 = 3/16
1110 = 2/16
1111 = 1/16
Movie Mode
Current
0000 = 100% (default)
0001 = 89.1%
0010 = 79.4%
0011 = 70.8%
0100 = 63.1%
0101 = 56.2%
0110 = 50.1%
0111 = 44.7%
1000 = 39.8%
1001 = 35.5%
1010 = 31.6%
1011 = 28.2%
1100 = 25.1%
1101 = 22.4%
1110 = 20%
1111 = 0%
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
14
202305C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 20, 2013