Table 3. SKY77324 Electrical Specifications (1) (9 of 9)
Parameter
Symbol
Test Condition
Time from POUT = –10 dBm to within
0.5 dBm of POUT = +1.5 dBm
Min.
Typ.
Max. Units
—
0.5
3.0
Open Loop(4) Switching time
τRISE, τFALL
Time from POUT = –10 dBm to within
0.5 dBm of POUT = +20.0 dBm
—
0.8
1.1
µs
Time from POUT = –10 dBm to within
0.5 dBm of POUT = +32.0 dBm
—
1.2
1.5
Spurious
All combinations of the following parameters:
VAPC = controlled (3)
Spur
PIN = min. to max.
No parasitic oscillation > –36 dBm
VCC = 2.9 V to 4.8 V
Load VSWR = 8:1, all phase angles
Load mismatch
All combinations of the following parameters:
VAPC = controlled (3)
Load
PIN = min. to max.
No module damage or permanent degradation
VCC = 2.9 V to 4.8 V
Load VSWR = 10:1, all phase angles
Noise power
PNOISE
Power control dynamic range
PCDR
Power control variation (5)
(Control level 0–8) 3.2 V ≤ VCC ≤ 4.5 V
PCV
Power control variation (5)
(Control level 9–13)
PCV
Power control variation (5)
(Control level 14–15)
PCV
Power control slope
PCS
Closed loop bandwidth
BCL
Loop phase margin
PM
At fO + 20 MHz
RBW = 100 kHz
VCC = 3.5 V
1.5 dBm ≤ POUT ≤ 32.0 dBm
TCASE = +25 °C
At 869 to 894 MHz
RBW = 100 kHz
VCC = 3.5 V
1.5 dBm ≤ POUT ≤ 32.0 dBm
TCASE = +25 °C
—
POUT +15.5 to +32.0 dBm, +25 °C
POUT +15.5 to +32.0 dBm
POUT +5.5 to +13.5 dBm, +25 °C
POUT +5.5 to +13.5 dBm
POUT +1.5 to +3.5 dBm, +25 °C
POUT +1.5 to +3.5 dBm
1.5 to 32.0 dBm
VAPC = 1.0 V
VAPC = 1.0 V
—
–82
–80
dBm
—
–97
–87
35
50
—
dB
–1.0
—
+1.0
dB
–1.6
—
+1.6
–1.8
—
+1.8
dB
–3.3
—
+3.3
–3.0
—
+3.0
dB
–4.5
—
+4.5
—
—
400
dB/V
—
500
—
kHz
75
—
—
deg.
(1) Unless specified otherwise:
TCASE = –20 °C to maximum operating temperature (see Table 2)
RL = 50 Ω
pulsed operation with pulse width ≤ 1154 µs and duty cycle ≤ 2:8
Vcc = 2.9 V to 4.8 V.
(2) Icc = 0A to xA, where x = current at POUT = 34.5 dBm, 50 Ω load, and Vcc = 3.5 V.
(3) Icc = 0A to xA, where x = current at POUT = 32.0 dBm, 50 Ω load, and Vcc = 3.5 V.
(4) This device has an Open Loop mode that allows bypassing of the internal PAC circuitry. See the Technical Information section at end of this document for further information.
(5) Power control variation is measured by comparing power obtained at a specified control voltage over all conditions, against the power obtained with the same control voltage at nominal
conditions. For this module, nominal conditions are defined as
T = 25 °C
VCC = 3.5 V
PIN = 3 dBm
Frequency = mid-band