English
Language : 

SBA-5089 Datasheet, PDF (2/5 Pages) List of Unclassifed Manufacturers – DC-5 GHz, Cascadable InGaP/GaAs HBT MMIC Amplifier
SBA-5089 DC-5 GHz Cascadable MMIC Amplifier
Preliminary
Typical RF Performance at Key Operating Frequencies
Frequency (MHz)
Symbol
Parameter
Unit
100
500
850
1950
2400
3500
G Small Signal Gain
dB
20.5
20.2
1F9.r9equency18(M.0Hz) 17.1
15.3
OIP3 Output Third Order Intercept Point dBm 36.3
35.8
36.0
34.0
32.7
30.9
P1dB Output Power at 1dB Compression dBm 19.8
19.8
19.7
19.5
18.8
17.1
IRL Input Return Loss
dB
29
27
25
20
17
11.8
ORL Output Return Loss
dB
27
21
17
11
11
11
S21 Reverse Isolation
NF Noise Figure
Test Conditions: VS = 8 V
RBIAS = 39 Ohms
dB
22
dB
4.1
ID = 80 mA Typ.
TL = 25ºC
22
23
23
23
23
4.3
4.2
4.5
----
----
OIP3 Tone Spacing = 1 MHz, Pout per tone = 0 dBm
ZS = ZL = 50 Ohms
Test Conditions:
Noise Figure vs. Frequency
6
5
4
3
+25c
-40c
+85c
2
0
0.5
1
1.5
2
Frequency (GHz)
Absolute Maximum Ratings
Parameter
Absolute Limit
Max.
Device
Current
(I )
D
Max. Device Voltage (VD)
Max. RF Input Power
130 mA
6V
+17 dBm
Max Operating Dissipated
Power
0.65 W
Max. Junction Temp. (TJ)
Operating Temp. Range (TL)
Max. Storage Temp.
+150°C
-40°C to +85°C
+150°C
Operation of this device beyond any one of these limits may
cause permanent damage. For reliable continous operation,
the device voltage and current must not exceed the maximum
operating values specified in the table on page one.
Bias Conditions should also satisfy the following expression:
I V < (T - T ) / R , j-l
DD
JL
TH
T =T
L LEAD
OIP3 vs. Frequency
38
+25c
36
-40c
+85c
34
32
30
28
26
0 0.5 1 1.5 2 2.5 3 3.5
Frequency (GHz)
P1dB vs. Frequency
21
+25c
20
-40c
+85c
19
18
17
16
15
0 0.5 1 1.5 2 2.5 3 3.5
Frequency (GHz)
303 South Technology Ct., Broomfield, CO 80021
Phone: (800) SMI-MMIC
2
http://www.sirenza.com