SP232A Datasheet, PDF (7/16 Pages) Sipex Corporation – Enhanced RS-232 Line Drivers/Receivers | |||
|
◁ |
VDD
a) C2+
GND
GND
b) C2â
Vss
Figure 6. Charge Pump Waveforms
that generate Vâ from V+ will show a decrease in
the magnitude of Vâ compared to V+ due to the
inherent inefficiencies in the design.
The clock rate for the charge pump typically
operates at greater than 15kHz. The external
capacitors can be as low as 0.1µF with a 10V
breakdown voltage rating.
Shutdown (SD) and Enable (EN) for the
SP310A and SP312A
Both the SP310A and SP312A have a shutdown/
standby mode to conserve power in battery-pow-
ered systems. To activate the shutdown mode,
which stops the operation of the charge pump, a
logic â0â is applied to the appropriate control line.
For the SP310A, this control line is ON/OFF (pin
18). Activating the shutdown mode also puts the
VCC= +5V
+
C1 â
â5V
+5V
+
C2 â
â5V
C4
+ â VDDStorage Capacitor
â + VSSStorage Capacitor
C3
Figure 7. Charge Pump â Phase 3
Vcc = +5V
+
C1 â
VDD
+
C2 â
C4
+ â VDDStorage Capacitor
â + VSSStorage Capacitor
C3
Figure 8. Charge Pump â Phase 4
Jan 31-07 Rev B
SP232A/233A/310A/312A