SP331 Datasheet, PDF (3/13 Pages) Sipex Corporation – Programmable RS-232/RS-485 Transceiver | |||
|
◁ |
Typically 25°C @ Vcc = +5V unless otherwise noted.
MIN. TYP. MAX.
RS-485 DRIVER
Balance
Common-Mode Output
Output Current
28.0
Short Circuit Current
±0.2
3.0
±250
AC Characteristics
Maximum Data Rate
Output Transition Time
Propagation Delay
tPHL
tPLH
Driver Output Skew
RS-485 RECEIVER
DC Characteristics
Inputs
Common Mode Range
Receiver Sensitivity
Input Impedance
10
30
50
80
120
80
120
10
20
â7.0
+12.0
±0.2
±0.3
12
15
AC Characteristics
Maximum Data Rate
10
Propagation Delay
tPHL
tPLH
Differential Receiver Skew
130
200
130
200
10
20
ENABLE TIMING
RS-485 Driver
Enable Time
Enable to Low
Enable to High
Disable Time
Disable From Low
Disable From High
90
150
90
150
80
120
80
120
ELECTRICAL CHARACTERISTICS
UNITS
CONDITIONS
Volts
Volts
mA
mA
|VT| - |VT|
RL=54â¦
Terminated in â7V to +10V
Mbps
ns
ns
ns
ns
RL=54â¦
Rise/fall time, 10%â90%
See Figures 2 & 4
RDIFF=54â¦, CL1=CL2=100pF
RDIFF=54â¦, CL1=CL2=100pF
per Figure 4, tSKEW = | tDPLH - tDPHL|
Volts
Volts
kâ¦
Mbps
ns
ns
ns
â7V ⤠VCM ⤠+12V
â7V ⤠VCM ⤠+12V
See Figures 2 & 6
RDIFF=54â¦, CL1=CL2=100pF
RDIFF=54â¦, CL1=CL2=100pF
tSKEW = | tPLH â tPHL |; RDIFF=54â¦,
CL1=CL2=100pF
See Figures 3 & 5
ns
CL=15pF, S1 Closed
ns
CL=15pF, S2 Closed
See Figures 3 & 5
ns
CL=15pF, S1 Closed
ns
CL=15pF, S2 Closed
POWER REQUIREMENTS
Supply Voltage VCC
+4.75
+5.25 Volts
Supply Current ICC
No Load (Tx Disabled)
10
15
mA
No Load (RS-232 Mode)
15
30
mA
No Load (RS-485 Mode)
7
20
mA
ENVIRONMENTAL
Operating Temperature
Commercial (..C..)
0
Industrial (..E..)
â40
Storage Temperature
â65
+70 °C
+85 °C
+150 °C
SEL_A ⨠SEL_D = "0001"
SEL_A ⨠SEL_D = "0000"
SEL_A ⨠SEL_D = "1100"
Date: 03-04-05
Programmable Dual RS-232/RS-485 Transceiver
3
© Copyright 2005 Sipex Corporation
|
▷ |