English
Language : 

SP42450 Datasheet, PDF (2/10 Pages) SIPAT Co,Ltd – SP5T Absorptive Silicon-on-Sapphire
Table 1. Electrical Specifications @ 25 °C, VDD = 3.0 V (ZS = ZL = 50 Ω )
Electrical Parameter
Path
Condition
Operating Frequency
Insertion Loss, IL
RFC - RFX
RFC - RFX
RFC - RFX
RFC - RFX
RFC - RFX
450 MHz
900 MHz
2100 MHz
2600 MHz
4000 MHz
Isolation, Iso
RFC/RFX - RFX
RFC/RFX - RFX
RFC/RFX - RFX
RFC/RFX - RFX
RFC/RFX - RFX
450 MHz
900 MHz
2100 MHz
2600 MHz
4000 MHz
Return Loss, Active Port
RFX
450 - 4000 MHz
Return Loss, Terminated Port
RFX
450 - 4000 MHz
Input 1 dB compression1, P1dB
RFX - RFC
All Bands,100% duty cycle
Input IP2
RFX - RFC
All Bands, 100% duty cycle
Input IP3
RFX - RFC
Switching Time, TSW
"On"
"Off"
Notes: 1. Please refer to Maximum Operating Power in Table 2
All Bands, 100% duty cycle
50% Control to 90% RF
50% Control to 10% RF
SP42450
High-Isolation RF Switch
Min Typ Max Unit
450
4000 MHz
1.6
1.8
dB
1.65
1.9
dB
1.95
2.15 dB
2.05
2.25 dB
2.25
2.55 dB
63
68
dB
57
62
dB
50
55
dB
50
53
dB
45
50
dB
16
dB
15
dB
35
dBm
95
dBm
58
dBm
200
500
ns
200
500
ns
Table 2. Operating Ranges
Parameter
Symbol Min Typ Max Units
VDD Supply Voltage
VssEXT Negative Power Supply
Voltage2
IDD Power Supply Current
VDD = 3.0 V, PIN= 0 dBm
IDD Max Power Supply Current
VDD = 3.3 V, PMAX= 33 dBm,
Temperature = -40°C
Control Voltage High
VDD 2.7 3.0 3.3
V
VssEXT -3.3 -3.0 -2.7 V
IDD
14
µA
IDD
(max)
VIH
0.7 x
VDD
50 µA
VDD
V
Control Voltage Low
VIL
0
ICTRL Control Current3
Maximum Operating Power (RFX
-RFC, All Bands (50Ω), 100%
duty cycle)
Maximum power into termination
(RFX, All Bands (50Ω),100%
duty cycle)
ICTRL
PMAX
PMAX
0.3 x
VDD
V
1 µA
33 dBm
24 dBm
Operating temperature range
TOP
-40
+85 °C
Note: 2.
3.
Applied only when external Vss power supply used. Pin 20
must be grounded when using internal Vss supply.
Pull-down resistor in EVK schematic may increase control
current.
Tel: +86-23-62808818 Fax: +86-23-62805284 www.sipatsaw.com / sawmkt@sipat.com Page 2 of 10