SI7021-A20 Datasheet, PDF (9/36 Pages) Silicon Laboratories – IC HUMIDITY AND TEMPERATURE SENSOR | |||
|
◁ |
Si7021-A20
Table 5. Temperature Sensor
1.9 ⤠VDD ⤠3.6 V; TA = â40 to +85 °C (G grade) or â40 to +125 °C (I/Y grade) default conversion time, unless otherwise noted.
Parameter
Operating Range
Symbol
Test Condition
I and Y Grade
Min Typ Max
Unit
â40
â +125
°C
Accuracy1
Repeatability/Noise
G Grade
â10 °C< tA < 85 °C
â40 < tA < 125 °C
14-bit resolution
â40
â
+85
°C
â ±0.3 ±0.4
°C
Figure 3
â 0.01 â
13-bit resolution
12-bit resolution
â 0.02 â
â 0.04 â
°C RMS
Response Time2
Ï63%
11-bit resolution
â 0.08 â
Unmounted device
â
0.7
â
s
Si7021-EB board
â
5.1
â
Long Term Stability
â ï£ 0.01 â
°C/Yr
Notes:
1. 14b measurement resolution (default).
2. Time to reach 63% of final value in response to a step change in temperature. Actual response time will vary
dependent on system thermal mass and air-flow.
Figure 3. Temperature Accuracy*
*Note: Applies only to I and Y grade devices beyond +85 °C.
Rev. 1.1
9
|
▷ |