The results of the temperature measurement may be converted to temperature in degrees Celsius (°C) using the
following expression:
Temperature (C  = 1----7---5----.-7----2----6--T--5--e-5---m3----6-p----_---C-----o---d---e-- – 46.85
Where:
Temperature (°C) is the measured temperature value in °C
Temp_Code is the 16-bit word returned by the Si7021
A temperature measurement will always return XXXXXX00 in the LSB field.