SI7006-A10 Datasheet, PDF (9/34 Pages) Silicon Laboratories – Excellent long term stability | |||
|
◁ |
Si7006-A10
Table 5. Temperature Sensor
1.9 ⤠VDD ⤠3.6 V; TA = â40 to +125 °C default conversion time unless otherwise noted.
Parameter
Symbol
Test Condition
Min Typ Max
Unit
Operating Range
Accuracy1
Repeatability/Noise
â10 °C< tA < 85 °C
â40 < tA < 125 °C
14-bit resolution
â40 â +125
°C
â ±0.5 ±1
°C
Figure 3
â 0.01 â
13-bit resolution
12-bit resolution
â 0.02 â
â 0.04 â
°C RMS
Response Time2
Long Term Stability
Ï63%
11-bit resolution
Unmounted device
Si7006-EB board
â 0.08 â
â
0.7
â
â
5.1
â
â ï£ 0.01 â
s
s
°C/Yr
Notes:
1. 14b measurement resolution (default).
2. Time to reach 63% of final value in response to a step change in temperature. Actual response time will vary
dependent on system thermal mass and air-flow.
Rev. 1.1
9
|
▷ |