English
Language : 

SI7006-A10 Datasheet, PDF (9/34 Pages) Silicon Laboratories – Excellent long term stability
Si7006-A10
Table 5. Temperature Sensor
1.9 ≤ VDD ≤ 3.6 V; TA = –40 to +125 °C default conversion time unless otherwise noted.
Parameter
Symbol
Test Condition
Min Typ Max
Unit
Operating Range
Accuracy1
Repeatability/Noise
–10 °C< tA < 85 °C
–40 < tA < 125 °C
14-bit resolution
–40 — +125
°C
— ±0.5 ±1
°C
Figure 3
— 0.01 —
13-bit resolution
12-bit resolution
— 0.02 —
— 0.04 —
°C RMS
Response Time2
Long Term Stability
τ63%
11-bit resolution
Unmounted device
Si7006-EB board
— 0.08 —
—
0.7
—
—
5.1
—
—  0.01 —
s
s
°C/Yr
Notes:
1. 14b measurement resolution (default).
2. Time to reach 63% of final value in response to a step change in temperature. Actual response time will vary
dependent on system thermal mass and air-flow.
Rev. 1.1
9