English
Language : 

SI7015-A10 Datasheet, PDF (7/39 Pages) Silicon Laboratories – Excellent long term stability
Si7015-A10
Table 4. Humidity Sensor
1.9 ≤ VDD ≤ 3.6 V; TA = 30 °C; default conversion time unless otherwise noted.
Parameter
Operating Range1
Accuracy2, 3
Symbol
Repeatability/Noise
Response Time4
Drift vs. Temperature
Hysteresis
Long Term Stability3
τ63%
Test Condition
Non-condensing
0 – 80% RH
80 – 100% RH
Normal Mode
Fast Mode
1 m/s airflow
Min Typ Max
0
—
100
— ±3.0 ±4.5
See Figure 2
— 0.05 —
—
0.2
—
—
18
—
— 0.05 —
—
±1
—
— < 0.25 —
Unit
%RH
%RH
%RH
%RH RMS
%RH RMS
S
%RH/°C
%RH
%RH/yr
Notes:
1. Recommended humidity operating range is 20% to 80% RH (non-condensing) over –10 °C to 60 °C. Prolonged
operation beyond these ranges may result in a shift of sensor reading with slow recovery time.
2. Excludes hysteresis, long term drift, and certain other factors and is applicable to non-condensing environments only.
See “4.2. Relative Humidity Sensor Accuracy” for more details.
3. Drift due to aging effects at typical room conditions of 30C and 30% to 50%. May be impacted by dust, vaporized
solvents or other contaminants, e.g., out-gassing tapes, adhesives, packaging materials, etc. See “4.9. Long Term
Drift/Aging”.
4. Response time to a step change in RH. Time for the RH output to change by 63% of the total RH change.
RHAccuracy
Max.RHError(±%)
Typ.RHError(±%)
10
9
8
7
6
5
4
3
2
1
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100
RelativeHumidity(%)
Figure 2. RH Accuracy at 30 °C
Rev. 1.0
7