English
Language : 

SI7015-A10 Datasheet, PDF (4/39 Pages) Silicon Laboratories – Excellent long term stability
Si7015-A10
1. Electrical Specifications
Unless otherwise specified, all min/max specifications apply over the recommended operating conditions.
Table 1. Recommended Operating Conditions
Parameter
Symbol Test Condition
Min
Typ
Max
Unit
Power Supply
VDD
1.9
—
3.6
V
Operating Temperature
TA
F grade
0
—
+70
°C
Operating Temperature
TA
G grade
–40
—
+85
°C
Table 2. General Specifications
1.9 < VDD < 3.6 V; TA = –40 to 85 °C (G grade) or 0 to 70 °C (F grade); default conversion time unless otherwise noted.
Parameter
Input Voltage High
Input Voltage Low
Input Voltage Range
Symbol
VIH
VIL
VIN
Test Condition1
AD0, SCL, SDA pins
AD0, SCL, SDA pins
SCL, SDA, RSTb pins with respect to
GND
Min
0.7xVDD
—
0.0
Typ
Max Unit
—
—
V
—
0.3xVDD V
—
VDD
V
Input Leakage
IIL
SCL, SDA pins; VIN = GND
CS pin (200K nominal pull up);
Vin = GND
—
—
5xVDD
1
μA
μA
Output Voltage Low VOL SDA pin; IOL = 2.5 mA; VDD = 3.3 V
—
SDA pin; IOL = 1.2 mA;
—
VDD = 1.9 V
Current
Consumption
IDD
RH conversion in progress
—
Temperature conversion in progress
—
—
0.6
V
—
0.4
V
150
180
µA
90
120
µA
CS < VIL; no conversion in progress;
—
VDD = 3.3 V;
SDA = SCL ≥ VIH; HEAT = 1
Standby2, –40 to +85°C
—
Peak IDD during powerup3
—
Peak IDD during I2C operations4
—
24
—
mA
0.06
0.62 µA
3.5
4.0
mA
3.5
4.0
mA
Conversion Time
tCONV
RH Normal (Fast = 0)
RH Fast (Fast = 1)
—
5.8
7.0
ms
—
2.6
3.1
ms
Temperature Normal (Fast = 0)
—
4.0
6.2
ms
Temperature Fast (Fast = 1)
—
1.5
2.4
ms
Notes:
1. Initiating a RH measurement will also automatically initiate a temperature measurement. The total conversion time will
be tCONV(RH) + tCONV(T).
2. No conversion or I2C transaction in progress. Typical values measured at 25 °C.
3. Occurs once during powerup. Duration is <5 msec.
4. Occurs during I2C commands for Read Device ID and Read Firmware Version. Duration is < 100 µs when I2C clock
speed is >100 kHz.
4
Rev. 1.0