English
Language : 

ISL6731A Datasheet, PDF (7/20 Pages) Intersil Corporation – Power Factor Correction Controllers
ISL6731A, ISL6731B
Absolute Maximum Ratings
VCC to GND. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3V to +28V
GATE to GND. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3V to +18V
VIN, BO, ISEN, FB, OVP, ICOMP, SKIP, VREG and
COMP to GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3V to +6.3V
ESD Rating
Human Body Model (Tested per JESD22-A114) . . . . . . . . . . . . . . .2.5kV
Machine Model (Tested per JESD22-A115). . . . . . . . . . . . . . . . . . . . 200V
Charged Device Model (Tested per JESD-C101E) . . . . . . . . . . . . . . . . 1kV
Latch-Up (Tested per JESD-78B; Class 2, Level A) . . . . . . . . . . . . . . 100mA
Thermal Information
Thermal Resistance (Typical)
JA (°C/W) JC (°C/W)
SOIC Package (Notes 4, 5) . . . . . . . . . . . . .
77
38
Maximum Junction Temperature (Plastic Package) . . . . . . . . . . . .+150°C
Maximum Storage Temperature Range . . . . . . . . . . . . . .-65°C to +150°C
Ambient Temperature Range . . . . . . . . . . . . . . . . . . . . . . .-40°C to +125°C
Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . .-40°C to +125°C
Pb-Free Reflow Profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . see TB493
Recommended Operating Conditions
VCC to GND. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12V to + 20V
Ambient Temperature Range . . . . . . . . . . . . . . . . . . . . . . .-40°C to +125°C
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product
reliability and result in failures not covered by warranty.
NOTES:
4. JA is measured with the component mounted on a high effective thermal conductivity test board in free air. See Tech Brief TB379 for details.
5. For JC, the “case temp” location is taken at the package top center.
Electrical Specifications Operating Conditions: VCC = 15V, TA = +25°C. Boldface limits apply across the operating temperature range,
-40°C to +125°C.
PARAMETER
SYMBOL
TEST CONDITIONS
MIN
MAX
(Note 8) TYP (Note 8) UNITS
VCC SUPPLY CURRENT
Start-Up Current
Standby Current
Skip Mode Current
Operating Current (Note 6)
VCC UVLO
ISTART
ISTDN
ICCSKIP
ICC
VFB = 1V, VCC < VCC(ON)
VFB = GND, VCC > VCC(ON)
VFB = 2.5V, COMP = SKIP*0.25 +1V
GATE is floating
73
106 139
µA
179 237 295 µA
580 690 850 µA
3.0
3.7
4.5
mA
UVLO Rising Threshold
UVLO Falling Threshold
UVLO Threshold Hysteresis
REGULATOR VOLTAGE VREG
VCC(ON)
VCC(OFF)
VCC(HYS)
9
10
11
V
6.7
7.5
8.3
V
2.5
V
Overall Accuracy
Current Limit
VREG IREG = 0 to -10mA, VCC = 15V, load capacitor = 47nF
5.1
5.4
5.6
V
30
50
70
mA
PWM CONVERTERS
Maximum Duty Cycle
OSCILLATOR
fSW = 124kHz for ISL6731A and
fSW = 62kHz for ISL6731B
94.8 96.5
%
Free Running Frequency, ISL6731A
Free Running Frequency, ISL6731A
Free Running Frequency, ISL6731B
Free Running Frequency, ISL6731B
PWM Ramp Amplitude
TA = -40°C to +125°C, VIN = 0.6V
TA = -40°C to +125°C, VIN = 2.5V
TA = -40°C to +125°C, VIN = 0.6V
TA = -40°C to +125°C, VIN = 2.5V
Vm
95.5 107 117 kHz
111 125 138 kHz
43.5 54 63.7 kHz
56.5 64 70.7 kHz
1.33 1.46 1.59
V
Submit Document Feedback
7
FN8582.1
February 13, 2015