English
Language : 

SI5316-EVB Datasheet, PDF (23/26 Pages) Silicon Laboratories – The Si531x/2x Any-Frequency Precision Clocks
Si531x-EVB Si532x-EVB
APPENDIX—POWERUP AND FACTORY DEFAULT SETTINGS
For the Si5324-EVB, Si5325/26-EVB, and Si5327-EVB, the power up settings are as follows:
19.44 MHz input on CKIN1
CKIN2 is not used because of free run mode
155.52 MHz output on CKOUT1
622.08 MHz output on CKOUT2
Loop BW of 70 Hz (Si5325/26-EVB)
Loop BW of 7 Hz (Si5324-EVB and Si5327-EVB)
LVPECL outputs for CKOUT1 and CKOUT2
For the Si5322/23-EVB, the factory jumper settings are as follows:
Pin
Jumper
Comment
AUTOSEL H
automatic, revertive
—
none
FRQSEL0
none
FRQSEL = LMLM
FRQSEL1
L
19.44 MHz input
FRQSEL2
none
155.52 MHz output
FRQSEL3
L
BWSEL0
H
BW is 96 Hz, the minimum
BWSEL1
H
CS_CA
none
CS_CA is an output, not an input
FRQTBL
L
SONET frequency table
—
none
SFOUT0
H
PECL outputs
SFOUT1
none
RATE0
none
114.285 MHz ref xtal
RATE1
none
DBL_BY
L
CKOUT2 enabled
—
none
INC
none
DEC
none
—
none
For the Si5319-EVB, the power up settings are as follows:
Free run mode, based on the 114.285 MHz crystal
19.44 MHz on CKOUT
Loop BW of 110 Hz
LVEPCL output for CKOUT
Rev. 0.6
23