English
Language : 

SI4707-B20 Datasheet, PDF (19/30 Pages) Silicon Laboratories – WEATHER BAND AND SAME DATA RECEIVER
Si4707-B20
5. Commands and Properties
Cmd
0x01
0x10
0x11
0x12
0x13
0x14
0x15
0x16
0x50
0x52
0x53
0x54
0x55
0x57
0x58
0x80
0X81
Table 11. Si4707 Command Summary
Name
POWER_UP
GET_REV
POWER_DOWN
SET_PROPERTY
GET_PROPERTY
GET_INT_STATUS
PATCH_ARGS
PATCH_DATA
WB_TUNE_FREQ
WB_TUNE_STATUS
WB_RSQ_STATUS
WB_SAME_STATUS
WB_ASQ_STATUS
WB_AGC_STATUS
WB_AGC_OVERRIDE
GPO_CTL
GPO_SET
Description
Powerup device.
Returns revision information on the device.
Powerdown device.
Sets the value of a property.
Retrieves a property’s value.
Read interrupt status bits.
Reserved command used for firmware file downloads.
Reserved command used for firmware file downloads.
Selects the WB tuning frequency.
Queries the status of the previous WB_TUNE_FREQ command.
Queries the status of the Received Signal Quality (RSQ) of the current
channel.
Returns SAME information for the current channel.
Queries the status of the 1050 Hz alert tone.
Queries the status of the AGC.
Enable or disable the WB AGC.
Configures GPO3 as output or Hi-Z.
Sets GPO3 output level (low or high).
Rev. 0.8
19