SI4712-B30 Datasheet, PDF (14/42 Pages) Silicon Laboratories – FM RADIO TRANSMITTER WITH RECEIVE POWER SCAN | |||
|
◁ |
Si4712/13-B30
Table 10. FM Receive Power Scan Characteristics1,2
(VDD = 2.7 to 5.5 V, VIO = 1.5 to 3.6 V, TA = â20 to 85 °C, FRF = 76â108 MHz)
Parameter
Symbol Test Condition Min Typ Max Unit
Tune and Signal Strength Measurement Time
per Channel
â
â
80
ms
Notes:
1. Settling time for ac coupling capacitors on the audio input pins after Receive to Transmit transition can take a few
hundred milliseconds. The actual settling time depends on the values of the ac-coupling capacitors. Using digital audio
input mode avoids this settling time.
2. Guaranteed by characterization.
Table 11. Reference Clock Characteristics
(VDD = 2.7 to 5.5 V, VIO = 1.5 to 3.6 V, TA = â20 to 85 °C, FRF = 76â108 MHz)
Supported Parameter
RCLK Frequency Range1,2
Frequency Tolerance1
Symbol
Test Condition
Min Typ
31.130 32.768
â50
â
Max
40,000
50
Unit
kHz
ppm
Notes:
1. Guaranteed by characterization.
2. The RCLK frequency divided by an integer number (the prescaler value) must fall in the range of 31,130 to 34,406 Hz.
Therefore, the range of RCLK frequencies is not continuous below frequencies of 311.3 kHz.
14