ï® Operation
1. Basic operation
The basic operation when VON / OFF ⥠VSH is shown as follows.
1. 1 When the power supply voltage (VDD) increases
The OUTn pin becomes release status if VDD is equal to or higher than the release voltage (+VDETn).
Table 9 Set Conditions at Releasing
Output Logic
Full charge all on
Full charge all off
VOUTn
VSS
High-Z
Nch n
On
Off
1. 2 When VDD decreases
The OUTn pin becomes detection status if VDD is equal to or lower than the detection voltage (âVDETn).
Table 10 Set Conditions at Detecting
Output Logic
Full charge all on
Full charge all off
VOUTn
High-Z
VSS
Nch n
Off
On
1. 3 When VDD ⤠minimum operation voltage
The OUTn pin voltage is indefinite.
Remark n = 1 to 3
2. ON / OFF pin
This pin starts and stops the S-8229 Series.
When VON / OFF is set to VSL or lower, the entire internal circuit stops operating, and Nch n (refer to Figure 1 in
"ï® Block Diagram") is turned off, reducing current consumption significantly.
The ON / OFF pin is configured as shown in Figure 9. The ON / OFF pin is not internally pulled up or pulled down,
so do not use the ON / OFF pin in the floating status. When not using the ON / OFF pin, connect the pin to the VDD
pin.
VDD
Remark n = 1 to 3
ON / OFF
Figure 9
VSS
9
|
▷ |