 Application Circuits
1. Detection of residual quantity of the battery used by LED
Rev.1.0_02
ROUT1 ROUT2 ROUT3
R1
C1
VDD
S-8229
Series
ON / OFF VSS
OUT1
OUT2
OUT3
LED1 LED2 LED3
Figure 12
Caution The above connection diagram and constant will not guarantee successful operation. Perform
thorough evaluation using the actual application to set the constant.
2. Change of detection voltage
When the detection voltage is changed by using a resistance divider, set RA ≤ 100 kΩ to prevent oscillation, as
shown in Figure 13.
The detection voltage after changing is calculated by using the following equation.
Detection voltage =
RA + RB
RB
× −VDETn + RA × IDD
ROUT1 ROUT2 ROUT3
RA
VDD
OUT1
RB
C1
S-8229
Series
OUT2
ON / OFF VSS
OUT3
Figure 13
Caution 1.
2.
Note that the detection voltage may deviate from the value determined by the ratio of RA and RB
in the case of the above connection diagram.
The above connection diagram and constant will not guarantee successful operation. Perform
thorough evaluation using the actual application to set the constant.
Remark n = 1 to 3