English
Language : 

S-7750C Datasheet, PDF (9/44 Pages) Seiko Instruments Inc – PROGRAMMABLE PORT CONTROLLER (PORT EXPANDER WITH BUILT-IN E2PROM CIRCUIT)
PROGRAMMABLE PORT CONTROLLER (PORT EXPANDER WITH BUILT-IN E2PROM CIRCUIT)
Rev.1.1_00
S-7750C
Table 10 Characteristics of Period
Item
Symbol
Min.
Typ.
Max.
Unit
Write period to E2PROM
tWR
−
2.0
5.0
ms
Delay time accuracy (short-time setting)*1
tDLY1
0.8×T
T
1.2×T
µs
Delay time accuracy (long-time setting)*1
tDLY2
0.8×LT
LT
1.2×LT
µs
Timeout*1
tOUT
−
9×LT
−
µs
*1. Refer to “Figure 16 Timer Setting Register DO7 to DO0 / E2PROM” “Figure 17 Example of Using Timer Setting for
DO7 to DO0 Register”.
T represents time reference (timer scale) in the short-time setting.
LT represents time reference (timer scale) in the long-time setting.
tWR
SCL
SDA
B0
Write Data
Stop Condition
Acknowledgement
Signal
Figure 9 Write Cycle Timing
Start Condition
Seiko Instruments Inc.
9