Table 10 Characteristics of Period
Item
Symbol
Min.
Typ.
Max.
Unit
Write period to E2PROM
tWR
â
2.0
5.0
ms
Delay time accuracy (short-time setting)*1
tDLY1
0.8ÃT
T
1.2ÃT
µs
Delay time accuracy (long-time setting)*1
tDLY2
0.8ÃLT
LT
1.2ÃLT
µs
Timeout*1
tOUT
â
9ÃLT
â
µs
*1. Refer to âFigure 16 Timer Setting Register DO7 to DO0 / E2PROMâ âFigure 17 Example of Using Timer Setting for
DO7 to DO0 Registerâ.
T represents time reference (timer scale) in the short-time setting.
LT represents time reference (timer scale) in the long-time setting.
tWR
SCL
SDA
B0
Write Data
Stop Condition
Acknowledgement
Signal
Figure 9 Write Cycle Timing