English
Language : 

S-5742NBL0I-Y3N2U Datasheet, PDF (7/21 Pages) Seiko Instruments Inc – HIGH-WITHSTAND VOLTAGE HIGH-SPEED
HIGH-WITHSTAND VOLTAGE HIGH-SPEED BIPOLAR HALL EFFECT LATCH
Rev.2.1_00
S-5742 I Series
 Magnetic Characteristics
1. Product with BOP = 1.8 mT typ.
Table 8
Item
Operation point*1
Release point*2
Hysteresis width*3
S pole
N pole
Symbol
BOP
BRP
BHYS
(Ta = +25°C, VDD = 12.0 V, VSS = 0 V unless otherwise specified)
Condition
Min.
Typ.
Max. Unit Test Circuit
−
0.3
1.8
3.3
mT
4
−
−3.3
−1.8
−0.3
mT
4
BHYS = BOP − BRP
−
3.6
−
mT
4
2. Product with BOP = 3.0 mT typ.
Table 9
Item
Operation point*1
Release point*2
Hysteresis width*3
S pole
N pole
Symbol
BOP
BRP
BHYS
(Ta = +25°C, VDD = 12.0 V, VSS = 0 V unless otherwise specified)
Condition
Min.
Typ.
Max. Unit Test Circuit
−
1.5
3.0
4.5
mT
4
−
−4.5
−3.0
−1.5
mT
4
BHYS = BOP − BRP
−
6.0
−
mT
4
3. Product with BOP = 6.0 mT typ.
Table 10
(Ta = +25°C, VDD = 12.0 V, VSS = 0 V unless otherwise specified)
Item
Symbol
Condition
Min.
Typ.
Max. Unit Test Circuit
Operation point*1 S pole
BOP
−
3.0
6.0
9.0
mT
4
Release point*2
N pole
BRP
−
−9.0
−6.0
−3.0
mT
4
Hysteresis width*3
BHYS
BHYS = BOP − BRP
−
12.0
−
mT
4
*1. BOP: Operation point
BOP is the value of magnetic flux density when the output voltage (VOUT) changes after the magnetic flux density applied
to this IC by the magnet (S pole) is increased (by moving the magnet closer).
VOUT retains the status until a magnetic flux density of the N pole higher than BRP is applied.
*2. BRP: Release point
BRP is the value of magnetic flux density when the output voltage (VOUT) changes after the magnetic flux density applied
to this IC by the magnet (N pole) is increased (by moving the magnet closer).
VOUT retains the status until a magnetic flux density of the S pole higher than BOP is applied.
*3. BHYS: Hysteresis width
BHYS is the difference of magnetic flux density between BOP and BRP.
Remark The unit of magnetic flux density mT can be converted by using the formula 1 mT = 10 Gauss.
7