S-8426AAA-J8T1X Datasheet, PDF (6/37 Pages) Seiko Instruments Inc – BATTERY BACKUP SWITCHING IC | |||
|
◁ |
BATTERY BACKUP SWITCHING IC
S-8426A Series
Rev.2.0_02
ï® Electrical Characteristics
1. S-8426AAA
Table 5 (1 / 2)
Item
Symbol
Conditions
Output voltage 1
Dropout voltage 1
Load stability 1
Input stability 1
Output voltage temperature
coefficient 1
Output voltage 2
Dropout voltage 2
Load stability 2
Input stability 2
Output voltage temperature
coefficient 2
Primary power input voltage
CS detection voltage
VRO
Vdrop1
ÎVRO1
ÎVRO2
ÎVRO
ÎTa ⢠VRO
VOUT
Vdrop2
ÎVOUT1
ÎVOUT2
ÎVOUT
ÎTa ⢠VOUT
VIN
âVDET1
CS release voltage
+VDET1
VIN = 6 V, IRO = 30 mA
VIN = 6 V, IRO = 30 mA
VIN = 6 V, IRO = 0.1 to 40 mA
VIN = 6 to 16 V, IRO = 30 mA
Ta = â40 to +85 °C
VIN = 6 V, IOUT = 50 mA
VIN = 6 V, IOUT = 50 mA
VIN = 6 V, IOUT = 0.1 to 60 mA
VIN = 6 to 16 V, IOUT = 50 mA
Ta = â40 to +85 °C
â
VIN voltage detection
â
RESET detection voltage
RESET release voltage
PREEND detection voltage
PREEND release voltage
Operating voltage
Detection voltage
temperature coefficient
Sink current
Leakage current
âVDET2
VOUT voltage detection
+VDET2
â
âVDET3
VBAT voltage detection
+VDET3
Vopr
Î â VDET1
ÎTa ⢠âVDET1
Î â VDET2
ÎTa ⢠âVDET2
Î â VDET3
ÎTa ⢠âVDET3
â
VIN or VBAT
Ta = â40 to +85 °C
Ta = â40 to +85 °C
Ta = â40 to +85 °C
ISINK
ILEAK
VDS = 0.5 V,
VIN = VBAT = 2.0 V
RESET
PREEND
CS
VDS = 16 V, VIN = 16 V
(Unless otherwise specified: Ta = 25 °C)
Min.
Typ.
Max.
Unit
Test
Circuit
4.900 5.000 5.100 V
1
â
356 474 mV 1
â
50
100 mV 1
â
5
20 mV 1
â
±100
â
ppm/
°C
1
4.900 5.000 5.100 V
1
â
401 540 mV 1
â
50
100 mV 1
â
10
30 mV 1
â
±100
â
ppm/
°C
1
â
â
16
V
1
4.410 4.500 4.590 V
2
+VOUT +VOUT +VOUT
à 0.93 à 0.95 à 0.97
V
2
2.842 2.900 2.958 V
2
2.994 3.068 3.142 V
2
2.058 2.100 2.142 V
2
2.154 2.207 2.260 V
2
1.7
â
16
V
2
â
±100
â
ppm/
°C
2
â
±100
â
ppm/
°C
2
â
±100
â
ppm/
°C
2
1.50 2.30
â
mA 3
1.50 2.30
â
mA 3
1.50 2.30
â
mA 3
â
â
0.1 μA
3
6
|
▷ |