English
Language : 

S-25A256B Datasheet, PDF (6/23 Pages) Seiko Instruments Inc – Function to prevent malfunction by monitoring clock pulse
FOR AUTOMOTIVE 125°C OPERATION SPI SERIAL E2PROM
S-25A256B
Rev.1.2_01
 AC Electrical Characteristics
Table 12 Measurement Conditions
Input pulse voltage
Output reference voltage
Output load
0.2 × VCC to 0.8 × VCC
0.5 × VCC
100 pF
Table 13
Ta = −40°C to +125°C
Item
Symbol
VCC = 2.5 V to 5.5 V
Unit
Min.
Max.
SCK clock frequency
fSCK
-
5.0
MHz
CS setup time during CS falling
tCSS.CL
90
-
ns
CS setup time during CS rising
tCSS.CH
90
-
ns
CS deselect time
tCDS
90
-
ns
CS hold time during CS falling
tCSH.CL
90
-
ns
CS hold time during CS rising
SCK clock time "H" *1
SCK clock time "L"*1
Rising time of SCK clock*2
Falling time of SCK clock*2
SI data input setup time
SI data input hold time
SCK "L" hold time during HOLD rising
tCSH.CH
90
tHIGH
90
tLOW
90
tRSK
-
tFSK
-
tDS
20
tDH
30
tSKH.HH
70
-
ns
-
ns
-
ns
1
μs
1
μs
-
ns
-
ns
-
ns
SCK "L" hold time during HOLD falling
tSKH.HL
40
-
ns
SCK "L" setup time during HOLD falling
tSKS.HL
0
-
ns
SCK "L" setup time during HOLD rising
tSKS.HH
0
Disable time of SO output*2
tOZ
-
Delay time of SO output
tOD
-
Hold time of SO output
tOH
0
Rising time of SO output*2
tRO
-
Falling time of SO output*2
tFO
-
-
ns
100
ns
70
ns
-
ns
40
ns
40
ns
Disable time of SO output during HOLD falling*2
tOZ.HL
-
100
ns
Delay time of SO output during HOLD rising*2
tOD.HH
-
50
ns
WP setup time
tWS1
0
-
ns
WP hold time
tWH1
0
-
ns
WP release / setup time
tWS2
0
-
ns
WP release / hold time
tWH2
30
-
ns
*1. The clock cycle of the SCK clock (frequency fSCK) is 1 / fSCK μs. This clock cycle is determined by a combination of
several AC characteristics. Note that the clock cycle cannot be set as (1 / fSCK) = tLOW (min.) + tHIGH (min.) by
minimizing the SCK clock cycle time.
*2. These are values of sample and not 100% tested.
Item
Write time
Table 14
Ta = −40°C to +125°C
Symbol
VCC = 2.5 V to 5.5 V
Unit
Min.
Max.
tPR
-
5.0
ms
6