English
Language : 

S-82A1AAB-I6T1U Datasheet, PDF (5/44 Pages) Seiko Instruments Inc – BATTERY PROTECTION IC FOR 1-CELL PACK
Rev.2.0_00
BATTERY PROTECTION IC FOR 1-CELL PACK
S-82A1A Series
Table 2 (2 / 2)
Product Name
Delay Time
Combination*1
0 V Battery
Charge Function*2
Power-down
Function*3
Release Condition Release Voltage of
of Discharge
Discharge
Overcurrent Status*4 Overcurrent Status*5
S-82A1AAB-I6T1U
S-82A1AAC-I6T1U
S-82A1AAD-I6T1U
S-82A1AAE-I6T1U
S-82A1AAF-I6T1U
S-82A1AAG-I6T1U
S-82A1AAH-I6T1U
S-82A1AAI-I6T1U
S-82A1AAJ-I6T1U
S-82A1AAK-I6T1U
(1)
Available
Unavailable
Load disconnection
VRIOV
(2)
Unavailable
Unavailable
Load disconnection
VRIOV
(2)
Unavailable
Unavailable
Load disconnection
VRIOV
(3)
Available
Unavailable
Load disconnection
VRIOV
(2)
Unavailable
Unavailable
Load disconnection
VRIOV
(2)
Unavailable
Unavailable
Load disconnection
VRIOV
(4)
Available
Unavailable
Load disconnection
VRIOV
(5)
Unavailable
Available
Load disconnection
VRIOV
(2)
Unavailable
Unavailable
Load disconnection
VRIOV
(2)
Available
Unavailable
Load disconnection
VRIOV
S-82A1AAL-I6T1U
(2)
Unavailable
Unavailable
Load disconnection
VRIOV
S-82A1AAM-I6T1U
(2)
Unavailable
Unavailable
Load disconnection
VRIOV
S-82A1AAN-I6T1U
(2)
Unavailable
Unavailable
Load disconnection
VRIOV
S-82A1AAO-I6T1U
(3)
Available
Unavailable
Load disconnection
VRIOV
S-82A1AAP-I6T1U
(1)
Available
Unavailable
Load disconnection
VRIOV
S-82A1AAQ-I6T1U
(6)
Unavailable
Unavailable
Load disconnection
VRIOV
S-82A1AAR-I6T1U
(3)
Unavailable
Unavailable
Load disconnection
VRIOV
S-82A1AAS-I6T1U
(5)
Unavailable
Available
Load disconnection
VDIOV1
S-82A1AAT-I6T1U
(7)
Unavailable
Unavailable
Load disconnection
VRIOV
S-82A1AAU-I6T1U
(8)
Available
Unavailable
Load disconnection
VRIOV
S-82A1AAV-I6T1U
(9)
Available
Unavailable
Load disconnection
VRIOV
S-82A1AAW-I6T1U
(8)
Available
Unavailable
Load disconnection
VRIOV
S-82A1AAX-I6T1U
(3)
Available
Unavailable
Load disconnection
VRIOV
S-82A1AAY-I6T1U
(10)
Available
Unavailable
Load disconnection
VRIOV
S-82A1AAZ-I6T1U
(10)
Unavailable
Unavailable
Load disconnection
VRIOV
*1. Refer to Table 4 about the details of the delay time combinations.
*2. 0 V battery charge function "available" / "unavailable" is selectable.
*3. Power-down function "available" / "unavailable" is selectable.
*4. Release condition of discharge overcurrent status "load disconnection" / "charger connection" is selectable.
*5. Release voltage of discharge overcurrent status "VDIOV1" / "VRIOV = VDD × 0.8 (typ.)" is selectable.
Remark Please contact our sales office for the products with detection voltage value other than those specified above.
5