Rev.1.0_01
ï® Absolute Maximum Ratings
Table 5
(Ta = +25°C unless otherwise specified)
Item
Symbol
Absolute Maximum Rating
Unit
VIN pin voltage
VIN
VSS â 0.3 to VSS + 3.3
V
CPOUT pin voltage
VCPOUT
VSS â 0.3 to VSS + 3.3
V
OUT pin voltage
VOUT
VSS â 0.3 to VSS + 3.3
V
VM pin voltage
VVM
VSS â 0.3 to VSS + 3.3
V
Operation ambient temperature
Topr
â40 to +85
°C
Storage temperature
Tstg
â40 to +125
°C
Caution The absolute maximum ratings are rated values exceeding which the product could suffer physical
damage. These values must therefore not be exceeded under any conditions.
ï® Thermal Resistance Value
Item
Junction-to-ambient thermal resistance*1
Symbol
θJA
Table 6
Condition
Board A
Board B
SOT-23-5
Board C
Board D
Board E
Board A
Board B
SNT-8A
Board C
Board D
Board E
*1. Test environment: compliance with JEDEC STANDARD JESD51-2A
Remark Refer to "ï® Power Dissipation" and "Test Board" for details.
Min. Typ. Max. Unit
â
192
â °C/W
â
160
â °C/W
â
â
â °C/W
â
â
â °C/W
â
â
â °C/W
â
211
â °C/W
â
173
â °C/W
â
â
â °C/W
â
â
â °C/W
â
â
â °C/W