6. Operation of power-on detection circuit
When power is applied to the S-35190A, the power-on detection operates to set “1” in the POC flag (B0 in the status
register 1). A 1 Hz clock pulse is output from the INT pin.
Status register 2 setting
32kE = 0, INT1AE = INT1ME = 0,
Change by reset command
INT1FE
INT pin
OFF
0.5 s 0.5 s
Figure 32 Output Timing of INT Pin during Operation of Power-on Detection Circuit
„ Function to Clock-Correction
The function to clock-correction is to correct advance/delay of the clock due to the deviation of oscillation frequency, in
order to make a high precise clock. For correction, the S-35190A adjusts the clock pulse by using a certain part of the
dividing circuit, not adjusting the frequency of the crystal oscillator. Correction is performed once every 20 seconds (or 60
seconds). The minimum resolution is approx. 3 ppm (or approx. 1 ppm) and the S-35190A corrects in the range of −195.3 to
+192.2 ppm (or of −65.1 to +64.1 ppm). (Refer to Table 12.) Users can set up this function by using the clock-correction
register. Regarding how to calculate the setting data, refer to “1. How to calculate”. When not using this function, be sure
to set “00h”.
Correction
Minimum resolution
Correction range
Table 12 Function to Clock-Correction
B0 = 0
Every 20 seconds
3.052 ppm
−195.3 to +192.2 ppm
B0 = 1
Every 60 seconds
1.017 ppm
−65.1 to +64.1 ppm