S-35190A Datasheet, PDF (10/53 Pages) Seiko Instruments Inc – 3-WIRE REAL-TIME CLOCK | |||
|
◁ |
3-WIRE REAL-TIME CLOCK
S-35190A
Rev.2.4_00
2. Configuration of command
8 types of command are available for the S-35190A, The S-35190A does Read/Write the various registers by inputting
these fixed codes and commands. The S-35190A does not perform any operation with any codes and commands other
than those below.
Table 9 List of Command
Fixed
Command
Data
Code C2 C1 C0
Description
B7
B6
B5
B4
B3
B2
B1
B0
0 0 0 Status register 1 access
0 0 1 Status register 2 access
RESET*1 12/ 24 SC0*2 SC1*2 INT1*3 INT2*3 BLD*4 POC*4
INT1FE INT1ME INT1AE 32kE SC2*2 SC3*2 INT2AE TEST*5
0 1 0 Real-time data 1 access
(year data to)
Y1
Y2
Y4
Y8 Y10 Y20 Y40 Y80
M1
M2
M4
M8 M10
â*6
â*6
â*6
D1
D2
D4
D8
D10 D20
â*6
â*6
W1
W2
W4
â*6
â*6
â*6
â*6
â*6
H1
H2
H4
H8
H10 H20 AM/ PM â*6
m1
m2
m4
m8 m10 m20 m40
â*6
s1
s2
s4
s8
s10 s20 s40
â*6
Real-time data 2 access
0 1 1 (hour data to)
0110
H1
H2
H4
H8
H10 H20 AM/ PM â*6
m1
m2
m4
m8 m10 m20 m40
â*6
s1
s2
s4
s8
s10 s20 s40
â*6
INT register 1 access
W1 W2 W4
â*6
â*6
â*6
â*6 A1WE
(alarm time 1: week/hour/minute)
(INT1AE = 1, INT1ME = 0,
H1
H2
H4
H8 H10 H20 AM/PM A1HE
1 0 0 INT1FE = 0)
m1 m2 m4 m8 m10 m20 m40 A1mE
INT register 1 access
(output of user-set frequency)
1 Hz 2 Hz 4 Hz 8 Hz 16 Hz SC4 *2 SC5 *2 SC6 *2
(INT1ME = 0, INT1FE = 1)
INT register 2 access
W1 W2 W4
â*6
â*6
â*6
â*6 A2WE
1 0 1 (alarm time 2: week/hour/minute) H1
H2
H4
H8 H10 H20 AM/PM A2HE
(INT2AE = 1)
m1 m2 m4 m8 m10 m20 m40 A2mE
1 1 0 Clock-correction register access
V0
V1
V2
V3
V4
V5
V6
V7
1 1 1 Free register access
F0
F1
F2
F3
F4
F5
F6
F7
*1. Write-only flag. The S-35190A initializes by writing â1â in this register.
*2. Scratch bit. A R/W-enabled, user-free register.
*3. Read-only flag. Valid only when using the alarm function. When the alarm time matches, this flag is set to â1â, and it is
cleared to â0â when Read.
*4. Read-only flag. âPOCâ is set to â1â when power is applied. It is cleared to â0â when Read. Regarding âBLDâ, refer to âÂ
Low Power Supply Voltage Detection Circuitâ.
*5. Test bit for SII. Be sure to set â0â in use.
*6. No effect by Write. It is â0â when Read.
10
Seiko Instruments Inc.
|
▷ |